17
.3
When drainage is necessary
If
water drainage is necessary in high
humidity district, remove the rubber cap
on the bottom of the chassis. Remove
the rubber cap from the bottom with a
plier. (Fig.7)
A hose of an appropriate length have to
be attached to the drain tray's drain
outlet. (Fig.8)
(1)
5
(2)
Install the cabinet into the installation
opening.(Fig.9)
Secure the cabinet to the mounting
frame using the 9 long gold screws.
(2.5cm/1"). (Fig.9)
Chassis
Rubber cap
Fig.7
Fig.8
Cabinet
Drain tray
Cabinet
Fig.9
Fig.6
Drain tray
Cabinet
Attach the provided drain tray to the
cabinet in case drainage becomes nec-
essary. Use the 2 short gold screws
(1.2cm/0.5") to fix it. (Fig.6)
4
Gasket
Drain tray can be attached in three
directions according to the installation
location of the air conditioner unit.
Attach drain tray in direction that its brim
will not hit upon the raised of cabinet
edge.
Raised portion
Fig.6-1
Fig.6-2
Fig.6-3
3
Remove the 3 fixing nuts and the fixing
angles from the compressor.(Fig.5)
T h e s e a r e f o r t h e p u r p o s e o f
transportation only. Keep them in a
handy place in case of re-location.
3 positions
Compressor
Fixing nut
Fixing angle
Rubber
Fig.5
Wrench