AE-X4M30PU
3
MODEL
ITEMS
INDOOR UNIT
OUTDOOR UNIT
AY-XPC07PU/09PU/12PU/15PU/18PU
AE-X4M30PU
Connections
Refrigerant coupling
Flare type
Refrigerant tube size
( Gas line)
7K, 9K, 12K
inch (mm)
3/8 ( 9.52)
15K, 18K
1/2 (12.7)
Refrigerant tube size (Liquid line)
inch (mm)
1/4 ( 6.35)
Minimum
-
Maximum length ( per unit)
ft ( m)
10 - 82 ( 3 -25)
Maximum length
2 units
ft ( m)
164 ( 50)
3 or 4 units
230 ( 70)
Maximum charge-less length
ft ( m)
164 ( 50)
Maximum height difference
ft ( m)
49 ( 15)
Additional charge
oz./ft ( g/m)
0.16 ( 15)
Drain pipe O.D.
inch (mm)
5/8 (16)
Others
Safety device
Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control, Pressure switch
Air fillters
Polypropylene net (Washable)
Net dimensions
(Width x Height x Depth)
07PU , 09PU ,
12PU
inch
(mm)
36-7/32 x 11-13/32 x 9-7/16
( 920 x 290 x 240)
35 x 31-1/2 x 12-19/32
( 890 x 800 x 320)
15PU , 18PU
inch
(mm)
38 x 12-5/16 x 9-27/32
( 965 x 313 x 250)
Net weight
07PU , 09PU ,
12PU
lb. (kg)
22 ( 10)
137 ( 62)
15PU
28.7 ( 13)
18PU
29.8 ( 13.5)
NOTE: Test conditions are based on AHRI 210/240. ( Refrigerant piping length [per unit] : 25ft[7.6m])
* : Voltage is 230V
: Representative connection