AE-X4M30PU
21
500k
400k
300k
200k
100k
0
-4
32 68
140 176 212 248
3.3kΩ
6.2kΩ
2.5kΩ
1.9kΩ
40k
30k
20k
10k
0
-4
32
68
140
104
(-20) (0) (20)
(60) (80)(100) (120)
(-20)
(0) (20)
(60)
(40)
TH1 : Compressor thermistor (CN8A 1 - 2 )
TH2 - TH4
TH6 - TH9
Temperature ºF (ºC)
Temperature ºF (ºC)
25ºC resistance
50.0 kΩ
TH-1
Resistance (
)
Resistance (
)
32ºF(0ºC)
resistance
14.5 kΩ
77ºF(25ºC)
resistance
4.431 kΩ
4.5kΩ
Figure 2 Temperature properties of outdoor thermistors
Connector
CN8A
Connector
CN8M
1
TH2 : Heat exchanger pipe thermistor (CN8A 3 - 4 )
TH3 : Outdoor temp. thermistor (CN8A 5 - 6 )
TH4 : Suction thermistor (CN8A 7 - 8 )
TH6 : Thermistor unit A (CN8M 1 - 2 )
TH7 : Thermistor unit B (CN8M 3 - 4 )
TH8 : Thermistor unit C (CN8M 5 - 6 )
TH9 : Thermistor unit D (CN8M 7 - 8 )
1
9
10
Thermistor
No.
Connector
Color
Connector pin
Compressor thermistor
TH1
CN8A
Red
No. 1 to 2
Heat exchanger pipe thermistor
TH2
CN8A
Orange
No. 3 to 4
Outdoor temp. thermistor
TH3
CN8A
Green
No. 5 to 6
Suction thermistor
TH4
CN8A
Black
No. 7 to 8
Thermistor unit A (suction)
TH6
CN8M
Blue
No. 1 to 2
Thermistor unit B (suction)
TH7
CN8M
White
No. 3 to 4
Thermistor unit C (suction)
TH8
CN8M
Brown
No. 5 to 6
Thermistor unit D (suction)
TH9
CN8M
Yellow
No. 7 to 8
1. How to distinguish the defective parts
1) When all rooms are not cooled
Yes
Yes
Yes
No
No
No
Are the timer lamps of the in-
door units in all rooms flashing ?
Is the compressor of the outdoor
unit operating ?
Are the timer lamps of the indoor
units in all rooms flashing ?
Check the failure symptom with
the failure diagnosis mode.
The cooling cycle is abnormal.
Check the pressure.
Check that the power between
the terminal board "L1" and "L2"
of the indoor unit is AC 230V,
60Hz.
Repair the wiring between the
units.
Press the OPERATION button to start
operating the air-conditioner.
(One-room operation ON)
(Set the cooling mode to 61ºF(16ºC))
(Check the failure with
the outdoor unit.)
TO
A