AYXPC18LR
4 – 2
[2] PERFORMANCE CURVES
NOTE: 1) Indoor fan speed: Hi
2) Vertical adjustment louver “45
°
“, Horizontal adjustment louver “front”
3) Indoor air temp.: Cooling 27
°
C, Heating 20
°
C
4) Power source: 230V, 50Hz
1. AY-XPC18LR
1.1. Cooling
1.2. Heating
Outside air temp.(ºC
)
Outside air temp.(ºC
)
Outside air temp.(ºC
)
Outlet
air
temp.(
ºC
)
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
6.2
20
25
30
35
40
45
50
Cooling
capacity
(kW)
1000
1100
1200
1300
1400
1500
1600
1700
20
25
30
35
40
45
50
Input(W)
10.0
11.0
12.0
13.0
14.0
15.0
16.0
20
25
30
35
40
45
50
Outside air temp.(
ºC)
Outlet
air
temp.(
ºC)
Outside air temp.(
ºC)
Outside temp.(
ºC)
2.4
2.8
3.2
3.6
4.0
4.4
4.8
5.2
5.6
6.0
6.4
-10
-5
0
5
10
15
Heating
capacity
(kW)
1100
1200
1300
1400
1500
1600
-10
-5
0
5
10
15
Input
(
᳑
)
28.0
30.0
32.0
34.0
36.0
38.0
40.0
-10
-5
0
5
10
15