AH/AY-AP18DR
AH/AY-AP24DR
36
Figure P-5. At Cooling for AH-AP18DR
Figure P-6. At Cooling for AH-AP24DR
REFRIGERANT PIPE INSTALLATION WORKS
Refrigerant pipe length and level difference between the indoor and outdoor units.
The shorter refrigerant pipe, the highter the machine capabillity. Keep the pipe line as short as possible.
If actual pipe length exceeds 7.5m, and refrigerant (R-410A) 15g per 1m.
Indoor air temp. : 27˚C
Indoor humidity : 47RH%
Indoor fan speed : Hi
Power supply : 50Hz, 220V
22000
23000
24000
Cooling capacity(BTU/h)
3000
6.0
6.5
7.0
(kW)
2000
Power input(W)
11
Outside air temp.(˚C)
Inside Outlet air temp.(˚C)
3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7
3 8 3 9 4 0
12
13
14
15
2500
Indoor air temp. : 27˚C
Indoor humidity : 47RH%
Indoor fan speed : Hi
Power supply : 50Hz, 220V
21000
16000
17000
18000
Cooling capacity(BTU/h)
2500
4.5
5.0
5.5
(kW)
1500
Power input(W)
11
Outside air temp.(˚C)
Inside Outlet air temp.(˚C)
3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7
3 8 3 9 4 0
12
13
14
15
2000
MODEL
AH-AP18DR
AH-AP24DR
PIPE SIZE
GAS
LIQUID
STANDARD PERMISSIBLE
LENGTH
PERMISSIBLE LEVEL
DIFERENCE
1/2"
1/2"
1/4"
1/4"
15m
10m
15m
10m