2.1 Precautions for temperature ,clearance space and installation environment
Measures against temperature
(
2
)
When installing the monitor, please secure Top/ Bottom/ Left/ Right clearances
and use it within the range of ambient temperature the chart below .
(Reference values)
*
The values in the chart are when it is not in the casing.
If you install with outer casing, requirements are changed by size/location of vent hole, whether there is
a fan or not.
The effectiveness of each measure differs depending on the environment. Please
choose the best measure for respective environment as follow.
- Using a cooling fan(However please note that the temperature inside the casing is
difficult to be lowered when dust is corrected and use the filter and clean it regularly.)
- Improve the ventilation by widening its space
- Using a heat exchanger
Heat prevention unit
(Apiste co.)
Example of fan installation
- If the temperature is too high
→
Electronic component’s life time will be
shortened or break down.
-If the temperature on LCD surface is too high
→
Monitors will break down or
uniformity issue will occur
- If the temperature is too low
→
Monitors will break down, will not start up or
monitor issue will occur.
The thermal influence
Temperature conditions
- Operating temperature range
※
1
→32°F (0
℃
)-104°F (40
℃
)
- Operating Humidity range
※
1
→20%-80%RH
(
No condensation
)
- Temperature of LCD surface
→ Below 140°F(60
℃
)
Please follow these requirements when setting the monitor. Refer to the
measures against temperature and install the monitor in accordance with its
requirements.
※
1: This range may change by installation conditions.
Measures against temperature
1
This monitor should be used at an ambient temperature between 32°F(0
℃
)
and 104°F (40
℃
).