15
15
Copyright © All rights reserved, SHARP CORPORATION
Confidential
Power Supply
Movable blade plug
Recommended
blade plug
No bushing
With bushing
Cautions for using a power strap
2.7 Precautions for power supply
- This monitor are designed to be used under commercial 100V-240V power supply, but shortage
of power supply may occur in wall video installation.
- Arrange plural circuit and level power consumption in each circuit.
- Prepare a spare ground wiring for maintenance to attach an earth strap.
- Check the neutral rating of the power strip and make sure that the total current consumption of
the connected equipment does not exceed the current value of the power strip.
- It is not recommended to use a power strip of a movable blade plug that moves the plug blade.
Prepare a spare ground wiring for maintenance to attach an earth strap. If an excessive load
is applied to the plug blade, abnormal heating may occur, even if the current is below the
rated current. Please use un-movable blade plug as much as possible.
- If the cord is pulled with an excessive force, the internal core wire may be damaged and
abnormal heat may occur, therefore it is recommended that the cord is fixed with a bushing or
the like.