background image

8

14LK20A

SERVICE ADJUSTMENT

VCO Adjustment

1. Connect a digital voltmeter between pin (44) of IC201

and ground.

2. Select a good local channel.
3. Enter the service mode and select the service

adjustment "S10".

4. Adjust the data so that digital voltmeter reads 2.2V.
5. Adjustment is completed, remove the voltmeter,

return to "normal" mode.

RF AGC Adjustment

1. Receive a good local channel.
2. Enter the service mode and select the service

adjustment "S08".

3. Set the data value to point where no noise or beat

appears.

4. Select another channel to confirm that no noise or

beat appears.
Note 1 : You will have to come out of the service

mode to select another channel.

Note 2 : Setting the data to "00" will produce a black

raster.

Screen  Adjustment

1. Connect a digital voltmeter between TP852 and

TP853 on the CRT Unit.
Note: These test points may not be provided.

Then connect the voltmeter to both ends of
R852 located near Q852 on the foil side.

2. Receive a good local channel.
3. Enter the service mode and select the service

adjustment "S03" and set the data value to "00" to
set the color level to minimum (Record original data
code under adjustment "S03" before changing). You
may skip this step, if you selected a B/W picture or
monoscope pattern.

4. Select the service adjustment "S19" and adjust the

data value to "01", this turn off the luminance signal
(Y-mute).

5. Select the service adjustment "S04" and adjust data

value to obtain 0.17 volts on the digital voltmeter.

6. Adjust the master screen control until the raster

darkens to the point where raster is barely seen.

7. Adjust the service adjustments "S11" red, "S12" green

and "S13" blue to obtain a good grey scale with
normal whites at low brightness level.

8. Select the service adjustment "S19" and reset data

to "00". Select the service adjustment "S03" and reset
data to obtain normal color level.

9. Remove digital voltmeter, and reset the master screen

control to obtain normal brightness range.

White Balance Adjustment

1. Receive a good local channel.
2. Enter the service mode and select the service

adjustment "S03" and set to "00" (minimum color).
"S03" does not have to be adjusted, if you selected a
B/W picture or monoscope pattern.

3. Alternately adjust the service adjustment data of "S14"

and "S15" until a good grey scale with normal whites
is obtained.

4. Select the service adjustment "S03" and adjust data

to obtain normal color level.

Sub-Picture Adjustment

1. Receive a good local channel.
2. Make sure the customer picture control is set to

maximum.

3. Enter the service mode and select the service

adjustment "S01".

4. Adjust the data value to achieve normal contrast

range.

Sub-Tint Adjustment

1. Receive a good local channel.
2. Set customer tint control to center of it's range.
3. Enter the service mode and select the service

adjustment "S02".

4. Adjust "S02" data value to obtain normal flesh tones.

Sub-Color Adjustment

1. Receive a good local channel.
2. Make sure the customer  color control is set to center

position .

3. Enter the service mode and select the service

adjustment "S03".

4. Adjust "S03" data value to obtain normal color level.

Summary of Contents for 14LK20A

Page 1: ... LIST 19 PACKING OF THE SET 25 Page CONTENTS SERVICE MANUAL MODEL POWER INPUT 110 220 V AC 50 60 Hz POWER RATING 63 W PICTURE SIZE 580cm2 89 8sq inch CONVERGENCE Magnetic SWEEP DEFLECTION Magnetic FOCUS Hi Bi Potential Electrostatic INTERMEDIATE FREQUENCIES Picture IF Carrier Frequency 45 75 MHz Sound IF Carrier Frequency 41 25 MHz Color Sub Carrier Frequency 42 17 MHz Nominal AUDIO POWER OUTPUT R...

Page 2: ...oes not exceed the specified value and that it is regulating correctly 5 Do not use a picture tube other than that specified or make unrecommended circuit modifications to the high voltage circuitry 6 When trouble shooting and taking test measurements on a receiver with excessive high voltage avoid being unnecessarily close to the receiver Do not operate the receiver longer than is necessary to lo...

Page 3: ...works mechanical insulators and etc 3 To be sure that no shock hazard exists check for leakage current in the following manner Plug theAC cord directly into a 110 120 voltAC outlet Do not use an isolation transformer for this test Using two clip leads connect a 1 5k ohm 10 watt resistor paralleled by a 0 15µF capacitor in series with all exposed metal cabinet parts and a known earth ground such as...

Page 4: ...4 14LK20A LOCATION OF USER S CONTROL ...

Page 5: ...rnal 26 8V DC at TP653 by using an external DC supply TV must be shut off 6 To reset the protector unplug the AC cord and make a short circuit between TP651 and TP652 Now make sure that normal picture appears on the screen 7 If the operation of the horizontal oscillator does not stop in step 5 the circuit must be repaired before the set is returned to the customer HIGH VOLTAGE CHECK High voltage i...

Page 6: ...tomer controls are in their proper reset position 2 Service number selection Once in the service mode press the Ch up or Ch down button on the remote controller or at the set The service adjustment number will vary in increments of one from S01 to M05 Select the item you wish to adjust 3 Data number selection Press the Vol up or down button to adjust the data number To enter the service mode and e...

Page 7: ...19 Y MUTE 00 00 01 03 00 NORMAL 01 No Y 03 No VERTICAL OP OPTION 80 00 FF Must be set to 08 M01 MTS LEVEL 0A 00 0F M02 STEREO VCO 20 00 3F M03 FILTER 1C 00 3F M04 LOW SEPARATION 20 00 3F M05 HIGH SEPARATION 1B 00 3F IC2001 IC2101 X CRT X IC201 Data is stored in IC2101 Adjust items related to picture tube only Table A Holding down both the Ch up down buttons on the TV set at service mode for more t...

Page 8: ...he digital voltmeter 6 Adjust the master screen control until the raster darkens to the point where raster is barely seen 7 Adjust the service adjustments S11 red S12 green and S13 blue to obtain a good grey scale with normal whites at low brightness level 8 Select the service adjustment S19 and reset data to 00 Select the service adjustment S03 and reset data to obtain normal color level 9 Remove...

Page 9: ...r the service mode and select the service adjustment S07 3 Adjust S07 data value so that picture is centered Caption Position Adjustment Horizontal 1 Receive a good local channel 2 Enter the service mode and select the service adjustment S18 3 A black text box appears on the screen see Figure B below 4 Adjust S18 data value so that text box is positioned in the center of the screen Figure B 3 58MH...

Page 10: ...10 14LK20A CHASSIS LAYOUT 6 5 4 3 2 1 A B C D E F G H ...

Page 11: ...11 14LK20A 6 5 4 3 2 1 A B C D E F G H BLOCK DIAGRAM ...

Reviews: