background image

7

14LK20A

SERVICE

 NUMBER

DATA

ADJUSTMENT CONTENTS

ADJUSTMENT ITEM

RANGE

INITIAL VALUE

S01

PICTURE

55

00-7F

S02

TINT

46

00-7F

S03

COLOR

32

00-7F

S04

BRIGHTNESS

40

00-7F

S05

SHARPNESS

28

00-3F

Must be set to "24"

S06

VERTICAL PHASE

00

00-07

Must be set to between "0" and "03"

S07

HORIZONTAL PHASE

12

00-1F

S08

RF-AGC

2A

00-3F

S09

VERTICAL AMP

20

00-3F

S10

VCO

2C

00-7F

S11

R CUT-OFF

00

00-FF

S12

G CUT -OFF

00

00-FF

S13

B CUT-OFF

00

00-FF

S14

G GAIN

7F

00-FF

S15

B GAIN

7F

00-FF

S16

TRAP(3.58MHz)

00

00 or 01

Must be set to "00"

S17

BALANCE

20

00-3F

Must be set to "20"

S18

C.C.POSITION

18

00-7F

S19

Y-MUTE

00

00,01,03

00=NORMAL, 01=No Y, 03=No VERTICAL

OP

OPTION

80

00-FF

Must be set to "08"

M01

MTS LEVEL

0A

00-0F

M02

STEREO-VCO

20

00-3F

M03

FILTER

1C

00-3F

M04

LOW SEPARATION

20

00-3F

M05

HIGH SEPARATION

1B

00-3F

IC2001

IC2101

X

CRT

X

IC201

Data is stored in IC2101.

Adjust items related to picture tube only.

Table - A

Holding down both the Ch-up/down buttons on the TV set at service mode for more than 2 seconds will automatically
write the above initial values into IC2101.

Table - B

The adjustment is needed to compensate for characteristics
of parts including IC201.

Holding down both the Ch-up/down bottons on the TV set in
the service mode for more than 2 seconds will automatically
write the above initial values into IC2101.

X

X

ADJUSTMENT

NECESSARY

UNNECESSARY

PART REPLACED

NOTES

Summary of Contents for 14LK20A

Page 1: ... LIST 19 PACKING OF THE SET 25 Page CONTENTS SERVICE MANUAL MODEL POWER INPUT 110 220 V AC 50 60 Hz POWER RATING 63 W PICTURE SIZE 580cm2 89 8sq inch CONVERGENCE Magnetic SWEEP DEFLECTION Magnetic FOCUS Hi Bi Potential Electrostatic INTERMEDIATE FREQUENCIES Picture IF Carrier Frequency 45 75 MHz Sound IF Carrier Frequency 41 25 MHz Color Sub Carrier Frequency 42 17 MHz Nominal AUDIO POWER OUTPUT R...

Page 2: ...oes not exceed the specified value and that it is regulating correctly 5 Do not use a picture tube other than that specified or make unrecommended circuit modifications to the high voltage circuitry 6 When trouble shooting and taking test measurements on a receiver with excessive high voltage avoid being unnecessarily close to the receiver Do not operate the receiver longer than is necessary to lo...

Page 3: ...works mechanical insulators and etc 3 To be sure that no shock hazard exists check for leakage current in the following manner Plug theAC cord directly into a 110 120 voltAC outlet Do not use an isolation transformer for this test Using two clip leads connect a 1 5k ohm 10 watt resistor paralleled by a 0 15µF capacitor in series with all exposed metal cabinet parts and a known earth ground such as...

Page 4: ...4 14LK20A LOCATION OF USER S CONTROL ...

Page 5: ...rnal 26 8V DC at TP653 by using an external DC supply TV must be shut off 6 To reset the protector unplug the AC cord and make a short circuit between TP651 and TP652 Now make sure that normal picture appears on the screen 7 If the operation of the horizontal oscillator does not stop in step 5 the circuit must be repaired before the set is returned to the customer HIGH VOLTAGE CHECK High voltage i...

Page 6: ...tomer controls are in their proper reset position 2 Service number selection Once in the service mode press the Ch up or Ch down button on the remote controller or at the set The service adjustment number will vary in increments of one from S01 to M05 Select the item you wish to adjust 3 Data number selection Press the Vol up or down button to adjust the data number To enter the service mode and e...

Page 7: ...19 Y MUTE 00 00 01 03 00 NORMAL 01 No Y 03 No VERTICAL OP OPTION 80 00 FF Must be set to 08 M01 MTS LEVEL 0A 00 0F M02 STEREO VCO 20 00 3F M03 FILTER 1C 00 3F M04 LOW SEPARATION 20 00 3F M05 HIGH SEPARATION 1B 00 3F IC2001 IC2101 X CRT X IC201 Data is stored in IC2101 Adjust items related to picture tube only Table A Holding down both the Ch up down buttons on the TV set at service mode for more t...

Page 8: ...he digital voltmeter 6 Adjust the master screen control until the raster darkens to the point where raster is barely seen 7 Adjust the service adjustments S11 red S12 green and S13 blue to obtain a good grey scale with normal whites at low brightness level 8 Select the service adjustment S19 and reset data to 00 Select the service adjustment S03 and reset data to obtain normal color level 9 Remove...

Page 9: ...r the service mode and select the service adjustment S07 3 Adjust S07 data value so that picture is centered Caption Position Adjustment Horizontal 1 Receive a good local channel 2 Enter the service mode and select the service adjustment S18 3 A black text box appears on the screen see Figure B below 4 Adjust S18 data value so that text box is positioned in the center of the screen Figure B 3 58MH...

Page 10: ...10 14LK20A CHASSIS LAYOUT 6 5 4 3 2 1 A B C D E F G H ...

Page 11: ...11 14LK20A 6 5 4 3 2 1 A B C D E F G H BLOCK DIAGRAM ...

Reviews: