IMPORTANT SERVICE SAFETY PRECAUTION

Ë

Service work should be performed only by qualified service technicians who are thoroughly
familiar with all safety checks and the servicing guidelines which follow:

X-RADIATION AND HIGH VOLTAGE LIMITS

1. Be sure all service personnel are aware of the

procedures and instructions covering X-radiation. The
only potential source of X-ray in current solid state
TV receivers is the picture tube. However, the picture
tube does not emit measurable X-Ray radiation, if
the high voltage is as specified in the "High Voltage
Check" instructions.
It is only when high voltage is excessive that X-
radiation is capable of penetrating the shell of the
picture tube including the lead in the glass material.
The important precaution is to keep the high voltage
below the maximum level specified.

2. It is essential that servicemen have available at all

times an accurate high voltage meter.
The calibration of this meter should be checked
periodically.

3. High voltage should always be kept at the rated value

no higher. Operation at higher voltages may cause

a failure of the picture tube or high voltage circuitry
and;also, under certain conditions, may produce
radiation in exceeding of desirable levels.

4. When the high voltage regulator is operating properly

there is no possibility of an X-radiation problem. Every
time a color chassis is serviced, the brightness should
be tested while monitoring the high voltage with a
meter to be certain that the high voltage does not
exceed the specified value and that it is regulating
correctly.

5. Do not use a picture tube other than that specified or

make unrecommended circuit modifications to the
high voltage circuitry.

6. When trouble shooting and taking test measurements

on a receiver with excessive high voltage, avoid being
unnecessarily close to the receiver.
Do not operate the receiver longer than is necessary
to locate the cause of excessive voltage.

WARNING

1. For continued safety, no modification of any circuit

should be attempted.

2. Disconnect AC power before servicing.
3. Semiconductor heat sinks are potential shock

hazards when the chassis is operating.

4. The chassis in this receiver has two ground systems

which are separated by insulating material. The non-
isolated (hot) ground system is for the B+ voltage
regulator circuit and the horizontal output circuit. The
isolated ground system is for the low B+  DC voltages
and the secondary circuit of the high voltage
transformer.
To prevent electrical shock use an isolation
transformer between the line cord and power
receptacle, when servicing this chassis.

SERVICING OF HIGH VOLTAGE SYSTEM
AND PICTURE TUBE

When servicing the high voltage system,
remove the static charge by connecting a
10k ohm resistor in series with an insulated
wire (such as a test probe) between the pic-
ture tube ground and the anode lead. (AC
line cord should be disconnected from AC
outlet.)

1. Picture tube in this receiver employs integral

implosion protection.

2. Replace with tube of the same type number for

continued safety.

3. Do not lift picture tube by the neck.
4. Handle the picture tube only when wearing

shatterproof goggles and after discharging the high
voltage anode completely.

Summary of Contents for 14LK20A

Page 1: ... LIST 19 PACKING OF THE SET 25 Page CONTENTS SERVICE MANUAL MODEL POWER INPUT 110 220 V AC 50 60 Hz POWER RATING 63 W PICTURE SIZE 580cm2 89 8sq inch CONVERGENCE Magnetic SWEEP DEFLECTION Magnetic FOCUS Hi Bi Potential Electrostatic INTERMEDIATE FREQUENCIES Picture IF Carrier Frequency 45 75 MHz Sound IF Carrier Frequency 41 25 MHz Color Sub Carrier Frequency 42 17 MHz Nominal AUDIO POWER OUTPUT R...

Page 2: ...oes not exceed the specified value and that it is regulating correctly 5 Do not use a picture tube other than that specified or make unrecommended circuit modifications to the high voltage circuitry 6 When trouble shooting and taking test measurements on a receiver with excessive high voltage avoid being unnecessarily close to the receiver Do not operate the receiver longer than is necessary to lo...

Page 3: ...works mechanical insulators and etc 3 To be sure that no shock hazard exists check for leakage current in the following manner Plug theAC cord directly into a 110 120 voltAC outlet Do not use an isolation transformer for this test Using two clip leads connect a 1 5k ohm 10 watt resistor paralleled by a 0 15µF capacitor in series with all exposed metal cabinet parts and a known earth ground such as...

Page 4: ...4 14LK20A LOCATION OF USER S CONTROL ...

Page 5: ...rnal 26 8V DC at TP653 by using an external DC supply TV must be shut off 6 To reset the protector unplug the AC cord and make a short circuit between TP651 and TP652 Now make sure that normal picture appears on the screen 7 If the operation of the horizontal oscillator does not stop in step 5 the circuit must be repaired before the set is returned to the customer HIGH VOLTAGE CHECK High voltage i...

Page 6: ...tomer controls are in their proper reset position 2 Service number selection Once in the service mode press the Ch up or Ch down button on the remote controller or at the set The service adjustment number will vary in increments of one from S01 to M05 Select the item you wish to adjust 3 Data number selection Press the Vol up or down button to adjust the data number To enter the service mode and e...

Page 7: ...19 Y MUTE 00 00 01 03 00 NORMAL 01 No Y 03 No VERTICAL OP OPTION 80 00 FF Must be set to 08 M01 MTS LEVEL 0A 00 0F M02 STEREO VCO 20 00 3F M03 FILTER 1C 00 3F M04 LOW SEPARATION 20 00 3F M05 HIGH SEPARATION 1B 00 3F IC2001 IC2101 X CRT X IC201 Data is stored in IC2101 Adjust items related to picture tube only Table A Holding down both the Ch up down buttons on the TV set at service mode for more t...

Page 8: ...he digital voltmeter 6 Adjust the master screen control until the raster darkens to the point where raster is barely seen 7 Adjust the service adjustments S11 red S12 green and S13 blue to obtain a good grey scale with normal whites at low brightness level 8 Select the service adjustment S19 and reset data to 00 Select the service adjustment S03 and reset data to obtain normal color level 9 Remove...

Page 9: ...r the service mode and select the service adjustment S07 3 Adjust S07 data value so that picture is centered Caption Position Adjustment Horizontal 1 Receive a good local channel 2 Enter the service mode and select the service adjustment S18 3 A black text box appears on the screen see Figure B below 4 Adjust S18 data value so that text box is positioned in the center of the screen Figure B 3 58MH...

Page 10: ...10 14LK20A CHASSIS LAYOUT 6 5 4 3 2 1 A B C D E F G H ...

Page 11: ...11 14LK20A 6 5 4 3 2 1 A B C D E F G H BLOCK DIAGRAM ...