USING A GENERATOR
Sharks generator is intended for private and hobby use. Before its use must be taken into account the
total wattage of all appliances planned to connect. The accuracy and appropriateness of use rather
consult a service technician Sharks (+ see. Info pp. 14-15). Overloading the generator as it may result
in a significant shortening the life of the machine or even permanent damage to the generator without
any claim on the guarantee!
Therefore, before connecting the appliance to the generator should make sure that its power does not
exceed the maximum rated output of the generator.
IMPORTANT: Most consumers need to start up to three times the power than the nominal power. Do
not exceed the prescribed limit load of individual outlets.
Only connect the generator to the appliances in mint fully functional condition. If the appliance has a
malfunction (sparks, excessive noise, etc.), Immediately turn it off or turn off the generator
immediately.
Select the appropriate sequence of when
connecting multiple appliances to the
generator.
WARNING: on the suitability of individual
consumers prefer to consult with an
electrician or service directly technically
Sharks.
Underestimating can lead to permanent
damage to the generator, which is not
warranted.
Connection must isolate the generator from the
current divorce ele. Current and must comply
with all laws and electrical codes.
WARNING!
Improper connection to the embedded
electrical system can allow electrical current
from the generator backward pass (break) in
wiring ele. current. Thus, reverse "puncture" kill utility company workers or others that affect leadership
during an outage ele. current. Consult a qualified electrician wiring!
WARNING!
Incorrect mains connection ele. current may cause "blowback" of distribution of electric current to the
generator. When the power supply restored, the generator may explode, burn or cause a fire ele.
divorce. In some areas there is a legal requirement of registration of generators power company.
Check local regulations, to be able to provide any registration and use the proper procedure of
participation and registration.
Grounding circuit generator
Portable generators have a grounding system that interconnects the components of the frame
generator to the grounding terminals of outlets of alternating current. The grounding system is not
connected to the neutral wire alternating current.
Local laws and regulations may require that the grounding system is connected to the neutral wire AC.
When the generator is tested socket tester does not show the same ground circuit condition as
domestic outlets.
If local regulations require grounding system connection to the neutral conductor of direct current,
consult connection with a qualified electrician or inspector.
Give him wiring diagram provided in this manual.
The grounding terminal may be used to ground the generator frame or a connection
generator to the vehicle frame, but only if it is required by local laws or regulations. Before using the
grounding terminal wiring, consult a qualified electrician or inspector.