CHARGER OPERATION
Before connecting the 230V/50Hz side ensure the cables are sound and not damaged.
Ensure electrical protection circuits.
1) Connect the battery charger to your battery, ensuring the battery voltage is within the
voltage ability of the unit i.e. 12V battery. Connect the charger to the 230V AC power, ensure
that you are in a dry environment and no water can cause electric shock. Connect the black
to the negative (-) terminal and the red to the positive (+) terminal. In the event of this being
incorrect, I.e. reverse polarity then the fault LED will flash. This indicates reverse polarity.
Please fix the polarity in this case.
2) After connecting the 230V the unit needs a few seconds to start. Also, from the start, if it
determines it is not a 12V or the battery is in such a bad state then the fault light will flash.
The charger will stop working. Assuming the charger has determined that all is ok then
simply leave the unit to do its job.
3) After completing the charge then simply remove the 230V AC first then remove the DC
cables.
TECHNICAL SPECIFICATIONS
Input voltage: 230V
output current: 0.8 A
fully automatic, microprocessor-controlled
LED display for 12 V battery
3 degree charge
Information LED charging status
fault diagnosis system
protection against overheating
short-circuit protection
reverse polarity protection