SSD • 9.801-194.0 • Rev. 12/13
OPERA
TOR’S MANU
AL
PRESSURE
W
ASHER
14
Air Shutter
Locking Screw
Air Shutter
Locking Screw
Air Band Locking
Screw
Air Shutter
Air Band
Reference Numbers
Air Band Locking Screws
Air Band
MAINTENANCE AND SERVICE
To adjust
, start the machine and turn burner ON.
Loosen two locking screws found in the air shutter
openings (see illustration) and close air shutter until
black smoke appears from burner exhaust vent. Note
air band position. Next, slowly open the air shutter until
white smoke just starts to appear. Turn air shutter half-
way back to the black smoke position previously noted.
Tighten locking screws.
If the desired position cannot be obtained using only
the air shutter, lock the air shutter in as close a position
as can be obtained, then repeat the above procedure
on the air band setting.
Shark Clear Flame Oil Burner
Burner Air Adjustment
: The oil burner on this machine
is preset for operation at altitudes below 1000 feet. If
operated at higher altitudes, it may be necessary to
adjust the air band for a #1 or #2 smoke spot on the
Bacharach scale.
To adjust, start machine and turn burner ON. Loosen
two locking screws found on the air band and close air
band until black smoke appears from burner exhaust
vent. Note air band position. Next, slowly open the air
band until white smoke just starts to appear. Turn air
band halfway back to the previously noted position.
Tighten locking screws.
Clear Flame Burner Air Adjustment
CAUTION:
If white smoke appears from burner ex-
haust vent during start-up or operation, discontinue
use and readjust air bands.
NOTE:
If a flue is installed, have a professional service-
man adjust your burner for a #1 or #2 smoke spot on
the Bacharach scale.