AFF/D 135
12-2-2015
-16-
Matt Asselman
ANGULAR STOP
1.
Loosen the nut on the protractor.
2.
Slide the nut into the desired position.
3.
Tighten the nut.
4.
Run the machine with a piece of test plastic, to check if the set angle is accurate enough.
If you do not wish to use the secondary bend, simple close the faucets on the left side of the
machine. The red faucet is for the vacuum (turning this 1 off is not mandatory to cancel the 2
nd
bend), the blue faucet is the flip-over system.
This cuts off the air supply to the secondary bend, and only the primary will be in use. Don’t
forget to turn off the heating element of the secondary bend as well!