AIR/TIMER UNIT
The air/timer unit is a combined unit for the control of the
topframe and to set the cycle time.
The machine closes, when the foot switch is used. The
timer will start when the machine is proper closed. The
machine opens again when the time reached its value. The
plastic sheet is then held into place by a vacum system,
and the flip is turned to bend the plastic sheet
automatically. The angle in which the sheet it bent can be
set manually (See 13.5). While the sheet is bent, cool air is
blown onto the crease to cool the sheet. The timer will
then reset back to zero
A.
Connection foot switch
B.
On/off switch
C.
Emergency button
D.
Timer unit
TIMER UNIT
Button
Function
Esc
cancel
+
increase value
-
decrease value
OK
confirm
►
move right
▼
move down
▲
move up
◄
move left
There are three numbers on the screen. From E
to G the number means the following; (see
10.4
)
E.
The time that the machine is closed. The time will start when the machine is entirely closed.
F.
The time that the flip is in the turned position, and the sheet is being cooled.
G.
The number of times the cycle has been repeated.
D
C
A
B
E
G
F