background image

PAGE 6

LUBRICATING THE TOOL

Disconnect the air supply from the tool before lubricating. 
Add a few drops of tool oil into the inlet.

Turn the tool so the inlet is facing up and put one drop of high speed spin-
dle oil into the air inlet. Never use detergent oil or additives. Operate the 
tool briefly after adding oil.

Wipe off excessive oil at the exhaust. Excessive oil will damage O-rings in 
the tool. If an in-line oiler is used manual lubrication through the air inlet is 
not required on a daily basis.

Many air tool users find it convenient to use an oiler to help provide oil 
circulation through the tool and increase the efficiency and useful life of the 
tool. Check oil level in the oiler daily.

Many air tool users find it convenient to use a filter to remove liquid and 
impurities which can rust or wear internal parts of the tool. A filter also 
increase the efficiency and lifespan of the tool. The filter must be checked 
on a daily basis and if necessary drained.

CORRECT CONNECTION OF THE TOOL

WWW.SGS-ENGINEERING.COM

Summary of Contents for SAT405

Page 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL SAT405 CLIP HEAD NAILER...

Page 2: ...ROBLEMS Indicates an immediately hazardous situation which if not avoided will result in death or serious injury DANGER WARNING NOTE Indicates a potentially hazardous situation which if not avoided co...

Page 3: ...handing the tool to another person 10 Never use tool if safety trigger or springs are inoperable missing or damaged Do not alter or remove safety trigger or springs Make daily in spections for free mo...

Page 4: ...P SAFETY TOOL Disconnect the air supply from the tool Empty the magazine Make sure the trigger and the safety move up and down without sticking Connect the air supply to the tool Depress the safety ti...

Page 5: ...l oil Attach a high flow quick connector fitting to the tool Empty the magazine Regulate the air pressure to obtain air pressure within the working pressure range at the tool Load fasteners into your...

Page 6: ...e oiler is used manual lubrication through the air inlet is not required on a daily basis Many air tool users find it convenient to use an oiler to help provide oil circulation through the tool and in...

Page 7: ...e on each side of tool A Fig 4 B Remove two nuts B Fig 4 C Slide magazine back off of nosepiece D After clearing bent fastener reverse above to reassemble CLEANING THE TOOL Disconnect tool before clea...

Page 8: ...PAGE 8 PARTS DIAGRAM WWW SGS ENGINEERING COM...

Page 9: ...PAGE 9 PARTS LIST...

Page 10: ...Worn or damaged o rings or seals Tighten screws Install overhaul kit Tool does nothing or operates sluggishly Inadequate air supply Inadequate lubrication Worn or damaged O rings or seals Verify scre...

Page 11: ...e equipment specified above conforms to the above European Communities Directive s and Standard s PLACE DATE Signature Robert Wyatt Company Secretary Derby UK 24th JUNE 2017 SGS Engineering UK Ltd SGS...

Reviews: