Victory Connections
The projector is fitted with a DMX512 and RS-232/423 input/output.
When making the start address settings, consider that 4 channels are used (channel 1 is not operatio-
nal in this version).
For connection in a DMX network always use balanced microphonic cables type RF 60/12 2x0.25mm
2
or similar and select a good quality to prevent malfunctioning of the projector.
To reduce interference it may be necessary to insert a network terminator on the last projector in the
DMX chain, realized with a 120
Ω
1/4W resistor placed between pins 2 and 3 of the DMX connector.
Warning: The screening part of the cable (braid) must NEVER be connected to the system
earth, since this would lead to malfunctioning of the projector and the control units.
P
U
S
H
P
U
S
H
P
U
S
H
DMX512 or RS-232 line
Victory
#1
Victory
#2
Victory
# n
RS-232
COMPUTER
OUT
25 PIN
CONNECTOR
PROJECTOR
5 PIN
CONNECTOR
COMMON
DIGITAL SIGNAL
TD 2
GND 7
5
4
3
2
1
socket pin out
pin 1
comm
pin 2
- DMX
+ RS-232
pin 3
+ DMX
+ RS-232
1 2
3
output
input
1
2
3
4
5
4
5