background image

21

Factory default 

When restoring the G-1 Beam (POI) to the factory defaults, the following settings will be set:

• 

DMX address = 1

• 

Startup mode = DMX

• 

Display saver = Off

• 

Flip screen = Off

• 

RDM device label = Fixture type name

• 

Internal program reset

Effects

Gobo wheel

The G-1 Beam gobo wheel consists of 19 gobos + oscillation 2 times open positions to control the shape of emitted light.

Color wheel

The color wheel consists of 14  open position to control the color of emitted light. In addition, the color wheel is optimized for 

split colors and color transitions.

High-precision pan and tilt 

Rapid pan and tilt movement with continuous bi-directional rotation in pan and 240° tilt.

Ultra high-speed strobe effect

The ultra high-speed strobe effect generates random strobe and pulse effects with variable speed.

Beam angle and aperture zoom

The G-1 Beam is equipped with a fixed 2.8° beam angle and an aperture pseudo zoom adjustable down to 0.3°.

Fixture properties

Summary of Contents for G-1 BEAM

Page 1: ...USER MANUAL MOVING HEADS SERIES G 1 BEAM G 1 BEAM POI ...

Page 2: ...ct to change without notice SGM and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The SGM logo the SGM name and all other trademarks in this document pertaining to SGM services or SGM products are trademarks o...

Page 3: ...ice 13 Connecting to a DMX control device 14 Configuring the device for DMX control 15 Internal programs 16 Pan Tilt positions 16 Connect disconnect head and base 17 Installing ceiling mount bracket 17 Labels and serial numbers 19 Gobo Wheel 20 Color Wheel 20 Fixture properties 21 Control menu 22 RDM 23 POI Permanent Outdoor Installation 24 Troubleshooting 27 Maintenance 28 Ordering Information 29...

Page 4: ...alls For Permanent Outdoor Installations POI ensure that the fixture is securely fastened to a load bearing surface with suitable corrosion resistant hardware For a temporary installation with clamps ensure that the quarter turn fasteners are turned fully and secured with a suitable safety cable The standard safety wire cable must be approved for a safe working load SWL of 10 times the weight of t...

Page 5: ...battery in microwave ovens high pressure containers or on induction cookware Immediately discontinue use of the battery if while using charging or storing the battery emits an unusual smell feels hot changes color or shape or appears abnormal in any other way Only charge the battery mounted in the fixture with the built in charger Do not use a third party charger Do not charge unattended Only char...

Page 6: ...alone programs Fully RDM implemented compliant with the USITT DMX512 standard Low power consumption with optional battery power source up to three batteries Removable base Built in wireless DMX POI n a Corrosion classified C5 M marine for coastal and offshore areas with high salinity POI only at 70 of luminous output under the manufacturer s test conditions Overview Illustrations might vary from r...

Page 7: ...tion High pressure water jets of water from any direction When selecting a location for the device ensure that It is situated away from public thoroughfares and protected from contact with people It has adequate ventilation It is not immersed in water When using standard fixtures outdoors or in wet locations ensure that For wireless DMX or standalone operation the DMX out cable is properly attache...

Page 8: ... not shown between the load bearing support structure and the safety wire attachment point on the device The safety cable not included in the package must Bear at least 10 times the weight of the device SWL Have a minimum gauge of 4 mm Have a maximum length free fall 30 cm 12 in CAUTION Always use a safety wire of a grade AISI 316 steel Make sure the slack of the safety wire is at a minimum Never ...

Page 9: ...d DMX out must be connected in order to maintain the IP65 rating The G 1 Beam without base or with ceiling mount bracket operates on 24V DC power with an external power supply See Installing the ceiling mount bracket on pages 17 18 for installation details NOTE In POI versions is it supplied a fixed chassis mounted with a bare ended power cable Connect the fixture to power by mounting a power conn...

Page 10: ...G 1 Beam runs on battery power when AC power is connected AC power will take over operation When AC power is disconnected the fixture will return to run on battery power if not discharged Having the G 1 Beam been turned off due to continuous resistance to the pan tilt forcing it away from position for a prolonged period the G 1 Beam can then be turned back on by sending a full reset by DMX only wh...

Page 11: ...se on page 17 1 Remove the screw TX25 next to the True1 power input 2 Remove four screws TX25 under the base and remove the bottom bracket part 3 Remove seven screws TX25 under the base WARNING Risk of electric shock Step 1 Step 2 Step 3 4 Carefully flip the top part of the base in the direction of the arrow Take into consideration the cables connected from the top part to the bottom part of the b...

Page 12: ...re assembled to comply with the IP65 requirements NB The base unit is vacuum tested through the head unit Only use the SGM Vacuum Test Kit or contact your local SGM dealer if no test kit is available Attach the head unit onto the base unit Prepare the head for vacuum test by removing rear plastic cover on the head Remove the plug from the vacuum connection on the rear of the head Connect the vacuu...

Page 13: ...urn on the G 1 Beam when running of cabled power press any button and the fixture will power on instantly Press any button to disable pan tilt it generates time out for 10 sec after which it will return to the correct position Active input type C The active input is displayed for quick and simple verification of the input status When DMX is displayed The fixture responds to data received through c...

Page 14: ...sions please refer to page 25 26 to see how to connect DMX and AC power Connecting a wireless transmitter POI n a The standard G 1 Beam is designed to look for wireless transmitters in connect state when this option is not yet enabled To connect the standard G 1 Beam to a wireless transmitter Log off the currently paired wireless transmitter see below Disconnecting a wireless transmitter Press the...

Page 15: ...e following G 1 Beam in the DMX chain should then be set to a DMX address of 113 101 12 113 113 as the first fixture uses all the first 12 DMX channels If two or more devices have the same DMX start address they will behave identically Incorrect settings will result in unpredictable responses from the lighting controller Address sharing can be useful for diagnostic purposes and symmetrical control...

Page 16: ...be used standalone without a controller There are seven internal programs ranging from simple continuous pan rotation and pan tilt circles to sequential fade with nine programmable position presets The table below shows the available programs Programming the position presets for the internal programs is performed by using the innovative SGM patented system which lets you determine the pan tilt pos...

Page 17: ...o AC power start removing the head from the base following the steps below 1 Loosen the two butterfly locks on the head bracket DETAIL C from the base DETAIL D 2 With a firm grip gently pull the head away from the base in a straight upwards movement CAUTION Be careful when connecting disconnecting the head from the base in order to avoid damaging the connectors between the head and the base Please...

Page 18: ...ad unit 3 Insert the four screws tighten with 1Nm of torque 4 Mount the wire harness to the trapeze shaped head part ensuring the connector is properly fitted 5 Insert the four screws tighten with 0 6Nm of torque NB Carefully observe that the orientation of the pilot hole on the ceiling mount bracket matches the pilot hole on the head unit see step 1 in the image below Installing the ceiling mount...

Page 19: ...es shipped without the base unit and fixtures shipped with the ceiling mount bracket the head unit will have an unique serial number Connecting ceiling mount bracket to DC power and DMX The wire harness on the ceiling mount bracket has two cables one which supplies power the other which supplies DMX Connecting power Use a 24 V DC power supply able to deliver the sufficient amount of power to the p...

Page 20: ...en Gobo 13 Gobo 14 Aperture 1 smallest Aperture 2 Aperture 3 medium Aperture 4 Open Aperture 5 largest Effect Area 1 position 1 2 3 Oscillate Effect Area 2 position 1 2 3 Oscillate Color 1 Congo Color 2 Red Color 3 Green Color 4 Blue Color 5 Orange Color 6 Light Green Color 7 Pink Color 8 Light Blue CTB Color 9 Lavender Purple Color 10 Fluorescent Green Color 11 Magenta Color 12 Cyan Color 13 Yell...

Page 21: ... Color wheel The color wheel consists of 14 colors open position to control the color of emitted light In addition the color wheel is optimized for split colors and color transitions High precision pan and tilt Rapid pan and tilt movement with continuous bi directional rotation in pan and 240 tilt Ultra high speed strobe effect The ultra high speed strobe effect generates random strobe and pulse e...

Page 22: ...O DMX Active Display DMX Active YES or NO Display Flip X Press ENTER to enable disable X Display Off X Press ENTER to enable disable X AC Power Loss UPS X Press ENTER to enable disable X Factory Default Reset the fixture to factory default settings See Factory default on page 21 Service PIN Service use only Contact your SGM dealer or SGM support to request the service pin Service Menu Service use ...

Page 23: ...ther Roll Other Light PWM Other PID Actions allowed Name 0x0082 GET SET Device label 0x0081 GET Manufacturer Label 0x00E0 GET DMX Personality 0x00E1 GET DMX Personality Description 0x0200 GET Sensor Definition 0x0201 GET SET Sensor Value 0x0080 GET Device Model Description 0x1001 SET Reset Device 0x0051 Parameter description PID Actions allowed Name 0x0090 SET Factory Defaults 0x0501 GET SET Displ...

Page 24: ...ed DMX RDM devices ensure DMX link is terminated and keep a short cable length as far as possible Regarding the DMX modes for POI they are the same as the standard G 1 Beam Visit www sgmlight com to see all DMX charts available under the respective product or upon request via support sgmlight com PLEASE NOTE Remote Device Management RDM requires a correct DMX cabled installation and termination Wh...

Page 25: ...red on without receiving DMX signal Static flashing red an error message is stored review via the SGM RDM Addressing Tool reboot the fixture or contact SGM support for diagnostic help Off fixture is off or indicator LED is set to off or auto dimming set via RDM Connecting DMX and AC power in POI DMX in and DMX out are in the same cable see figure 27 and the power is wired as the standard version S...

Page 26: ...eam POI EXTERNAL POWER SUPPLY AC POWER AC POWER Shield GND White DMX in Data Red DMX in Data Shield GND Black DMX out Data Yellow DMX out Data Junction box DMX cable DMX cable Shield GND White DMX in Data Red DMX in Data Shield GND Black DMX out Data Yellow DMX out Data Junction box ...

Page 27: ...ng The wireless transmitter or connections were disconnected tampered with Inspect the wireless transmitter and connections DMX cables were disconnected Inspect DMX cables Fixture operates irregularly abnormal DMX address or DMX mode is incorrect Inspect and enter the correct DMX address or mode DMX cable polarization is inverted pin 2 3 Install a phase inverter to reverse the polarity or replace ...

Page 28: ...er to ensure the IP rating of the G 1 Beam POI it s highly recommended that the fixture is always vacuum tested after installing or swapping any part that might compromise the IP rating SGM disclaims liability for any damage occasioned by the non use or inability to use the vacuum test kit after reassembling the fixture Cleaning SGM luminaires with IP65 or IP66 rating do not need any cleaning proc...

Page 29: ...n G 1 Beam POI accessories Omega bracket w Q bolt BL WH P N 83060602 83061206 Omega bracket POI with M10 Screws BL WH P N 83060623 83060624 2m power cable with Neutrik TRUE1 P N 07860040 SGM USB uploader cable P N 83062011 Ceiling mount for G 1 Series P N 83061707 1 pcs Battery Nominal 21 6V Nominal 3350 mAh P N 83061709 2 pcs Battery Nominal 21 6V Nominal 3350 mAh P N 83061710 Flightcase for 4 pc...

Page 30: ...30 User Notes ...

Page 31: ...31 User Notes ...

Page 32: ...32 SGM Light A S Sommervej 23 8210 Aarhus V Denmark Tel 45 70 20 74 00 info sgmlight com www sgmlight com ...

Reviews: