24
To stop the remaining fixtures from flashing, click ‘
Clear
’. It is important to note that the fixture(s) are not able to receive DMX
data until they stop flashing. This can take up to 5-6 seconds.
If you want to assign a new DMX address to a pre-assigned fixture, simply overwrite it by clicking ‘
Send
’ and assign it to a
new DMX address.
Click ‘
Unlink all fixtures from TX
’
to unlink all fixtures from an assigned DMX addresses. The fixtures will still have the
assigned DMX addresses, but they will not be active until you click the ‘Link’ button on the wireless Lumen Radio transmitter.
Interaction with R-2 Rail Light (hardware)
To physically unlink the R-2 Rail Light fixture:
1
Press the control button.
2
When the fixture starts flashing, press the button again to unlink the fixture.
To physically store current preset:
1
Press and hold the control button.
2
Wait for the fixture(s) to dim up and down, and then release the button.
Manual_R-2_170x113,3.book Page 24 Thursday, June 4, 2015 9:39 AM