12
Connecting AC Power
The R-2 Rail Light can operate on any 100–240V, 50/60 Hz AC mains power supply.
It draws approximately
0.2 amps
at full
power.
For permanent installation, have a qualified electrician wire the mains cable directly to a suitable branch circuit.
The fixture must be grounded/earthed and be able to be isolated from AC power. The AC power supply must incorporate a
fuse or circuit breaker for fault protection.
CAUTION:
Do not open the fixture, or connect the fixture to an electrical dimmer system, as this can damage it.
The power cable color coding is given below.
L2
L3
L1
N
Country or Region
Phase (L)
Neutral (N)
Protective
earth/ground
European Union (EU)
(brown)
(blue)
(green & yellow)
USA & Canada
(black)
(white)
(green)
Track rail power adaptor