27
FBI Super Fast Format
This DTMF format consists of 4-digit Account Codes, 2-
digit zone codes, 1-digit zone type codes, and 1-digit event
codes. The zone codes will be converted into 3-digit decimal
codes by the DRL2A.
The following are the zone type codes used by this format:
FBI
Code
Converted Event
Event
Code
Fire
1
A
Panic
2
A
Burglary
3
A
Medical
4
A
Auxiliary
5
A
Bypass
6
B
Inactive
7
A
Eight
8
A
Nine
9
A
Zero
0
A
Opening
B
O
Closing
C
C
Abort
D
T
Restore
E
R
Trouble
F
T
Note that option [3B] can give a unique FBI RS232 output
when enable.
ITI Format
The ITI format covers ITI panels model: RF Commander, Caretaker Plus, SX-1VB, SX-V, Commander III, Commander 2000,
Security Pro 5000 and UltraGard 5000. In order to receive the ITI format, handshake #10 must be programmed. After a
coldboot, the fifth handshake (option [45]) is programmed as 10.
ITI LIBRARY
ITI LIBRARY
ITI LIBRARY
ITI LIBRARY
ITI LIBRARY
SENSOR No.
SENSOR No.
SENSOR No.
SENSOR No.
SENSOR No.
PRINTED OUT AS
PRINTED OUT AS
PRINTED OUT AS
PRINTED OUT AS
PRINTED OUT AS
SPECIFICS
SPECIFICS
SPECIFICS
SPECIFICS
SPECIFICS
00
00 Buddy Alarm xx
SX-V only
01-32
XX ALM
Caretaker plus
00-16
XX ALM
RF Commander / Commander III
02-07
XX ALM
SX-IVB
01
BAD SENSOR #
SX-V only
02-76
XX ALM
SX-V
10-18
XX ALM
Commander 2000
01-76
XX ALM
UltraGard 5000
77
77 Alram Tmpr / Supervisory / CANC
Caretaker plus, SX-IVB, SX-V UltraGard 5000 only
78
78 TRB
Caretaker plus, UltraGard 5000 only
79
79 No activ alm / CANC
Caretaker plus, UltraGard 5000 only
80
80 Alarm
All supported ITI panels
81
81 Alarm
All supported ITI panels
82
82 Alarm
All supported ITI panels
83
83 Phone Tst
All supported ITI panels
84
84 OpenUsr xx
All supported ITI panels
85
85 CloseUsr xx
All supported ITI panels
86
86 SilentDuress
All supported ITI panels
87
87 ForceArmed / AutoForceArm
All supported ITI panels
88
88 TRB
Caretaker plus, UltraGard 5000 only
89
89 TRB
Caretaker plus, UltraGard 5000 only
90
90 AC Fail / RESTR
All supported ITI panels
91
91 Low CPU Bat / RESTR
All supported ITI panels
92
92 AlmTamprLoop / RESTR
All supported ITI panels
93
93 AutoPhoneTst
All supported ITI panels
94
94 TRB
All supported ITI panels
95
95 CPU Back In / 95 RESET
All supported ITI panels
96
Failure to communicate
Local alarm only
97
No phone line
Local alarm only
98
98 Event Dump Report
Commander 2000
Modem II, Modem IIE,Modem IIIa
2
and BFSK Formats
The alarm signals sent by the D2112, D4112, D6112, D7112,
D7212, D8112, D9112, Discovery 1000, NAPCO 3000 and
Honeywell D5700 using Modem II or Modem IIE formats
can be decoded by the DRL2A.
The printer messages will be similar to the following:
Modem II Single Line Example:
L01-1234-CLOSING
ID 801 14:04:20-09/13
BFSK Example:
L01-123-CLOSING
ID1
15:19:23-10/06
Modem II Double Line Example:
L01-1234-ALARM REPORT
14:05:20-09/13
AREA=1
POINT=008
14:05:21-09/13
• L01 represents Line 01
• 1234 represents the account codes.
The Signals will be sent to the computer according to Option
[59]:
If Option [59] = 00:
1011ssssssAAAAXXYYYY[DC4]
If Option [59] = 01:
6011ssssssAAAAXXYYYY[DC4]
Following the example described above, the signal will be
sent to the computer as:
1011ssssss1234sAs300[DC4]
or
6011ssssss1234sAs300[DC4]
NOTE:
The DRL2A will not follow the listen-in time sent by
any transmitter even though the time is printed. The DRL2A
will follow its own audio duration programmed at location
[49].