background image

18

Option [32]: Communication Select

If the MLR2-DG Receiver is not to be used with central
station automation software and a computer, program Option
[32] as “00”.

If the MLR2-DG is to be used with central station automation
software, program Option [32] with one of the values listed
below:

Value

Function

00

No communication to computer

01

Alarms communicated to computer. If the
alarm is reported in 3/1, 3/1 extended, 3/2 or
3/8 ACRON formats, a leading space will be
communicated in front of the 3-digit Account
Codes when sent to the computer

Ex:

1011ssssss

s

AAAsXsssY[DC4]

02

Alarms communicated to computer. If the alarm is
reported in 3/1 3/1 extended, 3/2 or 3/8 ACRON
formats, a leading “0” (zero) will be communicated
in front of the 3-digit Account Codes

Ex:

1011ssssss

0

AAAsXsssY[DC4]

03

Alarms communicated to computer. If the alarm
is reported in 3/1, 3/1 extended, 3/2 or 3/8
ACRON formats, a leading “0” (zero) will be
communicated in front of the 3-digit Account
Codes. If the alarm is reported in  3/1 or 4/1
formats, a leading “0” (zero) will be
communicated in front of the 1-digit alarm code

Ex:

1011ssssss

0

AAAsXss

0

Y[DC4]

[DEFAULT 01]

Option [33]:  Printer Enable: Communicate Information
to Printer Through CPM2

If a printer is not used with the MLR2-DG, program Option
[33] as “00”.

If a printer is to be used with the MLR2-DG, program Option
[33] with one of the values listed below:

00

Printer not selected

01

Printer selected

[DEFAULT 01]

Option [34]:  Receiver Number

The Receiver Number is used for sending signals to the
central station software. This number should be the same
for all DRL2A Line Card modules connected to the same
CPM2.

Refer to the manuals for any central station automation
software being used to determine if there are any special
requirements for this number. Also, check the numbers used
for any other receivers in the station to ensure that numbers
are not duplicated.

[DEFAULT 01]

Option [35]:  Line Card Number

The Line Card Number provides a unique identification code
for each Line Card in the DRL2A module. Since the CPM2
can be connected to a total of 14 Line Cards, it is very
important to program a unique code for each of the Line
Cards. Failure to do so will cause “clashes”, where two
Line Cards answer the same CPM2 polling message at the
same time. Hexadecimal numbers “01” to “0E” can be
programmed in Option [35] to identify Line Cards 01 through
14.

Option [36]:  Caller Identification (Call Display) Option

Option [36] allows the Line Card to receive Caller Identification

data that is transmitted after the first ring on the telephone
line.

Program “01” to enable this feature, or program “00” to
disable it. The “Call Display” service must be available and
requested from the Telephone Company for this feature to
be operational.

Program Option [36] with one of the following:

00

No reception

01

Normal reception operation with checksum verify

02

Reception without checksum verify
The following library messages are used with
Option [36]:

PrivateCall

:

An anonymous indication is received instead

of the originating telephone number

No call no.:

An out-of-area  or unavailable indication is

received instead of the originating telephone number

UnknownCall:

The originating telephone number has not

been received or was not transmitted

[DEFAULT 00]

Option [37]:  Send Caller-Identification (Telephone
number) to Computer

The DRL2A can send the Caller-Identification numbers to
the computer. If the telephone number is not received, the
Caller Identification information will not be sent to the
computer.

Program Option [37] with one of the following:

00

Do not send Caller Identification

01

Send Caller Identification for every call

02

Send Caller Identification only when fault call or
fault data is received

03

Send Caller Identification for every call without
the “1” long distance indicator

04

Send Caller Identification only when fault call or
faulty data is received, and send the information
without the “1” long distance indicator

Note that option [36] must be programmed as "01".

[DEFAULT 00]

Option [38]:  Send Caller Identification to Printer

To use Option [38], Option [36] must be programmed as
“01”.

Program Option [38] with one of the following:

00

Do not send Caller Identification to printer

01

Send alarm code and Caller Identification to printer
instead of the english alarm message. The printer
library must be removed at option [30]. Note that
10-40 baud and 4/3 formats only will be printed
with Caller Identification. Contact ID and SIA formats
will be printed with two lines. The first line will be
the alarm message and the second line will be
the caller-ID.

02

Send Caller Identification to printer only when fault
call or faulty data is received

[DEFAULT 00]

Option [39]:  Line Check

The Line Card will perform a telephone line test every 10
seconds. When Option [39] is enabled, if the line is faulty,
a warning message will be displayed on the Line Card
screen and an alarm will be sent to the computer and the
printer.   When option is disabled, no alarm will be transmitted.

Summary of Contents for MLR2-DG

Page 1: ...MLR2 DG Multi Line Receiver Installation Manual N EW Softw are Version See page 1 for new features and changes Version 1 8x 1 81SV Listed...

Page 2: ...ologu Cette tiquette certifie que le mat riel est conforme certaines normes de protection d exploitation et de s curit des r seaux de t l communications Industrie Canada n assure toutefois pas que le...

Page 3: ...ion 53 4 1 Express Format 21 Option 54 Reserved for future use 21 Option 55 Inter Digit time 21 Option 56 Group Arming Disarming with User Code 21 Option 57 4 3 Format User Conversion 3 digit Alarm Co...

Page 4: ...ontrast 33 Option 12 UL Receiver Option 33 Option 13 Erase Alarm Message Buffer 33 Option 14 Mute Buzzer 34 Option 15 Display Last Message 34 Option 16 ComPort Diagnostics 34 Option 17 Test 9V 12V Bat...

Page 5: ...receiver also provides a basic communication protocol similar to the RADIONICS 6500 interface for other software packages that have yet to be updated to include the Sur Gard interface CPM2 Outputs The...

Page 6: ...Operator Acknowledge option Telephone Line Supervision All formats noted as optional are selected using configuration commands System Overview Caller Identification Call Display capability Non Volatil...

Page 7: ...Gard RS 232 Communication Protocol to send signals to the computer if connected If a computer is not connected press the ACK button on the CPM2 module to silence the buzzer The time and date of the Ac...

Page 8: ...ng System power supply rated 12VDC Connect the positive lead from the DC supply to the BLGT terminal connect the negative lead from the DC supply to the GND terminal CAUTION Connecting a positive term...

Page 9: ...eplaced remove the temporary battery so that the CPM2 can properly maintain the main battery To Remove a Line Card Module Remove the 4 retaining screws from the front panel of the module Slowly pull t...

Page 10: ...so used for Downlook video communication or to remotely cancel an audio session TxPG1 12V programmable outputs These terminals are also used for Downlook video communications when Downlook TxPG2 is be...

Page 11: ...7 MLR2 DG BACKPLANE CONNECTION DIAGRAM Connections for DML2A Line Card Expansion...

Page 12: ...erial link for video monitoring control The DRL2A acts as an interface between the digital alarm transmitter and the CPM2 Different communication formats can be used to transmit the information The ma...

Page 13: ...owledge an alarm in emergency manual mode In the normal mode press this button to access the Line Card Menu ALARM The Alarm light is located inside the ACK FUNCTION button The Alarm light will flash i...

Page 14: ...ffer this message will be displayed L01 Digital Rec L01 Digital Rec L01 Digital Rec L01 Digital Rec L01 Digital Rec CPM Error CPM Error CPM Error CPM Error CPM Error If alarm messages cannot be sent t...

Page 15: ...essage displayed press the SELECT button the current Line Card Configuration will be displayed Press the ACK button to scroll forward through the configuration displays or press the SELECT button to s...

Page 16: ...problem is encountered the following information is transmitted to the printer and the computer Printer L0X 10 Fault Data Computer 0000 T 10 This output for account code 0000 indicates that data has...

Page 17: ...to p 25 Example Reserve a block of account codes such as 800 9FF for 3 digit formats or 7000 8FFF for 4 digit formats for panels which can communicate in 2 Way Audio Audio Mode Operation When in Audio...

Page 18: ...the wire from the p l a t e S c r e w s indicated with arrows in Fig 2 Remove the plate from the line card The plate is still attached to the line card through a flat ribbon wire and power wires Do n...

Page 19: ...n entered press and hold the Ack and Cancel Select button at the same time until this message is displayed TURN OFF SWITCH TURN OFF SWITCH TURN OFF SWITCH TURN OFF SWITCH TURN OFF SWITCH 7 Turn Off Sw...

Page 20: ...shown below LCard 01 Comd F7 LCard 01 Comd F7 LCard 01 Comd F7 LCard 01 Comd F7 LCard 01 Comd F7 Op 36 Cd __ Sc __ Op 36 Cd __ Sc __ Op 36 Cd __ Sc __ Op 36 Cd __ Sc __ Op 36 Cd __ Sc __ Enter the val...

Page 21: ...through 2F program ASCII codes according to the Decoding Library Values other than 20 7F ASCII and will not be accepted Note that the old value programmed in each Option will not be changed until a c...

Page 22: ...dentification Call Display Option Option 36 allows the Line Card to receive Caller Identification data that is transmitted after the first ring on the telephone line Program 01 to enable this feature...

Page 23: ...ble of sending several handshakes to a dialer Often it is important which handshake is sent first Program Options 41 through 46 according to your applications If all six Options are programmed as 00 2...

Page 24: ...ation of the 2 Way Audio feature For example if an Account on Line Card 01 activates the 2 Way Audio mode and Option 4D is programmed as 50 ASCII P the following messages will be sent Sent to computer...

Page 25: ...1234 C 16 1234 O2 32 instead of 1234 O 02 and 1234 O 32 If a user code is not received after the group opening closing the message 1234 C1 FF will be sent FF indicates that a user code was not receiv...

Page 26: ...mber AAAA Account code s Space CCCC Channel 1 4 s Space CCCC Channel 5 8 s Space C Channel 9 DC4 Terminator DEFAULT 00 Option 5C PGM Input When programming the option 5C to 01 the RxRngX input termina...

Page 27: ...FA 05 XX The LC FA 05 XX command will send the specified number of Caller Identification and corresponding alarm messages to the printer XX should be a hexadecimal number from 01 to FE to indicate a n...

Page 28: ...est L01 1234 00 24HrsTest 1234 T 00 1234 BBBB BBBB Low Battery L01 1234 B0 LwBattery 1234 T B0 1234 0700 0000 Alarm Zone 2 L01 1234 72 AlarmZn 2 1234 A 72 with alarm Code 7 NOTE When option 5A is prog...

Page 29: ...37 Exp Mod DC Loss 338 Exp ModLow Batt 339 Exp Mod Reset 341 Exp Mod Tamper Communication Troubles 350 and 360 350 Communication 351 Telco 1 fault 352 Telco 2 fault 353 Long range radio 354 Fail to co...

Page 30: ...B 01 Printer 1234 31 UnBypZn 01 Computer 1234 H 01 4 Closing report in the previous 8 channels with user ID in channel 1 if expanded reporting of user is selected at the communicator Printer 1234 41...

Page 31: ...2 Alarm All supported ITI panels 83 83 Phone Tst All supported ITI panels 84 84 OpenUsr xx All supported ITI panels 85 85 CloseUsr xx All supported ITI panels 86 86 SilentDuress All supported ITI pane...

Page 32: ...any displayable ASCII characters except the with option 31 SIA option for Level 2 3 decoding enabled 01 and an account code with a maximum of 6 digits with option 31 disabled 00 If option 31 SIA leve...

Page 33: ...For Alarm Corresponding Event Message Code Code Options 20 2F Default Other Alarm 0xx Axx T 0 Alarm 1xx A 1 Alarm 2xx A 2 Alarm 3xx A 3 Close 4xx C 4 Open 5xx O 5 Alarm 6xx T 6 Alarm 7xx A 7 Alarm 8xx...

Page 34: ...le and efficient Several diagnostics modes are available to assist the operator in troubleshooting and maintenance Features Multi tasking allows the receiver to perform functions that might otherwise...

Page 35: ...mode a message similar to this will be displayed FEB 23 07 30 45 FEB 23 07 30 45 FEB 23 07 30 45 FEB 23 07 30 45 FEB 23 07 30 45 Scanning 0E 14 Scanning 0E 14 Scanning 0E 14 Scanning 0E 14 Scanning 0...

Page 36: ...e will be displayed Prter Config As Prter Config As Prter Config As Prter Config As Prter Config As Bkup 0 Enable 1 Bkup 0 Enable 1 Bkup 0 Enable 1 Bkup 0 Enable 1 Bkup 0 Enable 1 Enter a digit from 0...

Page 37: ...yed this message will be displayed Com 2 Format is Com 2 Format is Com 2 Format is Com 2 Format is Com 2 Format is 0 Change to x 0 Change to x 0 Change to x 0 Change to x 0 Change to x Enter a number...

Page 38: ...s feature on Com1 or 2 for Com2 All data being sent through COM1 will now be displayed on the screen A typical transmission is shown here 1RRL AAAAsX 1RRL AAAAsX 1RRL AAAAsX 1RRL AAAAsX 1RRL AAAAsX YY...

Page 39: ...To change the receiver number press the ACK button when the 23 Chg Receiver message is displayed This message will be displayed Receiver Number Receiver Number Receiver Number Receiver Number Receive...

Page 40: ...be used to install a remote acknowledge button when using the receiver in manual mode Message Priorities When in Stand By Mode the CPM2 will display warning and other operational messages according t...

Page 41: ...Cd are used to indicate the Option number and the new code programmed for that option Sc Sc is used with SCADA applications Enter digits using the keypad when a digit is entered the cursor will move...

Page 42: ...nication between the CPM2 and the Line Cards The CPM2 also monitors the connection to the computer by sending a supervisory heartbeat signal through COM1 every 30 seconds If the heartbeat transmission...

Page 43: ...a Code Definitions YYYY Zone codes Leading spaces will be sent if zone codes are less than four digits If no zone codes are received from the control panel ss00 will be sent DC4 Terminator 14 Hex The...

Page 44: ...in Transmission SRRL 1234 Lri1BA01 DC4 or SRRL 1234 Nri1BA01 L90 DC4 Where S Protocol identifier for SIA protocol 2 RR Receiver number 01 FE L Line number 1 E Beginning data delimiter Account ID bloc...

Page 45: ...CCC Channel 1 4 s Space CCCC Channel 5 8 s Space C Channel 9 DC4 Terminator 14 Hex Acron Super Fast Protocol 9RRLssssAAAACCCCCCCC DC4 Where 9 Protocol number RR Receiver number L Line number ssss Spac...

Page 46: ...ber are calculated as follows Reported Number Group User Byte 0 9 0 9 10 35 A Z 36 61 a z 62 and greater Please take note that the DRL2A will not respond to any interactive commands from the ITI panel...

Page 47: ...ing F400 Automatic opening F1zz Normal closing ID ZZ F5zz Normal opening ID ZZ F2zz Forced closing ID ZZ F6zz Forced opening ID ZZ F3zz Supervised closing ID ZZ F7zz Supervised opening ZZ FD0a Closing...

Page 48: ...Card 04 at 01 45 650D 650E 0200H Test Line Card 05 at 02 00 650F 6510 0215H Test Line Card 06 at 02 15 6511 6512 0230H Test Line Card 07 at 02 30 6513 6514 0245H Test Line Card 08 at 02 45 6515 6516 0...

Page 49: ...is used to transport the alarm data from a local satellite central station to the master central station reliably by using linked Modem over leased phone lines This system is specifically intended to...

Page 50: ...46 UPS Connection...

Page 51: ...oth are 19 rack mount and should be located in the same cabinet as the MLR2 receiver A four wire connection must be made between the MLRXV or MLR2XV backplane board and the back plane board of the DRL...

Page 52: ...accessed by the use of a mouse or by a touch screen monitor The complete software and all individual icons and commands can be password protected Up to 8 images can be viewed at a time on one screen a...

Page 53: ...01 35 LCARD NUMB 00F 36 CALLER ID 000 37 TEL RS 232 000 38 TEL PRINTR 000 39 LINE CHECK 001 3A PGM OUTPUT 000 3B FBI RS232 000 3C FILTER OPT 000 3D BOOST SIGNL 000 3E MUTE BUZZER 000 3F LST MSG ON 000...

Page 54: ...02 System Passwords CAFE 03 Number of Line Cards E 04 Printer Select Backup 0 Enable 1 05 COM1 Configuration Baud 1200 Data 7 bits Parity 2 06 COM1 Format 1 07 ACK Wait Delay 4 0 seconds 08 Heartbeat...

Page 55: ...the DRL2A handshakes Ensure that the handshake is being sent at the proper positions 4th 5th or 6th position Ensure that the security control panel does not hand up before it receives the handshake C...

Page 56: ...ACK Level 1 2 3 space 300bps 14 Contact ID Dual Tone DTMF DTMF 4 2 1 3 2 3 NO 1400Hz 1400Hz 15 Sur Gard 2300Hz DTMF DTMF 4 1 4 2 4 3 NO 2300Hz 16 Sur Gard Dual Tone DTMF DTMF 4 1 4 2 4 3 NO 1400Hz 14...

Page 57: ...1000 121 79 0111 1001 122 7A 0111 1010 123 7B 0111 1011 124 7C 0111 1100 125 7D 0111 1101 126 7E 0111 1110 127 7F 0111 1111 DEC HEX BINARY 128 80 1000 0000 129 81 1000 0001 130 82 1000 0010 131 83 10...

Page 58: ...2 2 B3 33 3 B4 34 4 B5 35 5 B6 36 6 B7 37 7 B8 38 8 B9 39 9 C1 41 A C2 42 B C3 43 C C4 44 D C5 45 E C6 46 F C7 47 G C8 48 H C9 49 I CA 4A J CB 4B K CC 4C L CD 4D M CE 4E N CF 4F O D0 50 P D1 51 Q D2 5...

Page 59: ...uyer and is and shall be in lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of Sur Gard Ltd This warranty contains the entire...

Page 60: ...1998 PRINTED IN CANADA Sur Gard Security Systems Ltd 29001543 R2 October 29 1998...

Reviews: