SFC Energy EFOY Pro Installation Manual Download Page 13

Installation space requirements 

 

4.3

 

Necessary air inlets and outlets 

 

INFO 

 

The EFOY fuel cell requires incoming air and produces exhaust heat and 
exhaust gases.

 

 

If installing the fuel cell in enclosed areas, always plan an inlet for incoming 
air, an outlet for exhaust heat and an opening for the exhaust gas hose. 

 

To avoid any build-up of heat, ensure that the installation space is adequately 
ventilated, e.g. through an additional opening and a temperature-controlled 
fan. 

 

Protect the opening from any water infiltration and foreign objects, e.g. by 
using a gill plate and fly screen. 

Inlet and outlet dimensions 

Incoming air inlet 

Ø

 at least 10 cm 

 

Exhaust heat outlet 

Ø

 at least 10 cm 

See 

SECTIO

5.3 for installation 

information. 

Exhaust gas hose outlet 

Ø

 1 cm 

See 

SECTIO

5.4 for installation 

information. 

 

 

 

 

Before drilling or sawing breakthroughs, ensure that there is enough space behind 
the installation position. 

 

 

 

Summary of Contents for EFOY Pro

Page 1: ...Safety instructions...

Page 2: ...l cell is intended for operation in well ventilated environments and requires sufficient incoming air which is free of exhaust gas The device must be protected against direct weather influences especi...

Page 3: ...must be supervised to ensure that they do not play with the device Read the instructions before operating the device Do not expose the device to rain Transport in an upright position only Service and...

Page 4: ...distance between the device and side wall 15 4 5 Positioning the EFOY fuel cartridge 16 4 6 Permissible installation angle 17 5 Installing the EFOY fuel cell 18 5 1 Attaching the EFOY fuel cell using...

Page 5: ...d with a medium degree of risk which if not avoided can result in death or serious injury Pay attention to the danger warning CAUTION Indicates a hazard with a low degree of risk which if not avoided...

Page 6: ...s Only use the exhaust gas hose supplied Lead exhaust gases from the installation space to the open air DANGER Risk of electric shock The EFOY fuel cell is not waterproof The combination of infiltrati...

Page 7: ...ube and exhaust gas hose Observe the instructions for the respective sealant Ensure sufficient ventilation 1 4 Safety instructions for the electronics and battery DANGER Risk of fire Incorrectly laid...

Page 8: ...and sparks While charging the battery ensure sufficient ventilation Observe the battery manufacturer s safety information WARNING Risk of fire Non rechargeable batteries may not be charged with the E...

Page 9: ...nd free of gasoline and other sources of ignition Protect the EFOY fuel cell and EFOY fuel cartridges from temperatures over 50 C DANGER Risk of poisoning Breathing in touching or swallowing methanol...

Page 10: ...OP Set A B D A 1 EFOY fuel cell 2 EFOY service fluid C 7 Outer cover 8 Exhaust heat tube 9 Bluetooth adapter 10 Fuel cartridge holder incl belt BT set only B 3 Exhaust heat elbow 4 Insulated exhaust...

Page 11: ...ping tool 0 75 mm and 4 mm cable diameter Battery terminals to connect to your battery Sealant Scissors or cutter The following screws should be used depending on the substrate screws are not included...

Page 12: ...ommended distance to battery As close as possible The product contents include a 3 meter cable Up to 3 m 1 The installation space is given for an EFOY fuel cell including an M5 or M10 fuel cartridge 2...

Page 13: ...at the installation space is adequately ventilated e g through an additional opening and a temperature controlled fan Protect the opening from any water infiltration and foreign objects e g by using a...

Page 14: ...oval 4 Wastewater exhaust gases Exhaust heat and exhaust gases can be extracted from the installation space either at the side or through the base The exhaust gas condensate is also produced here can...

Page 15: ...ce between the device and side wall Allow for the following safe distance between the side wall and the EFOY fuel cell and fuel cartridge when planning the installation Short side distance at least A...

Page 16: ...inlet and 1 and exhaust heat outlet 2 as well as the electrical connections 3 may not be blocked by a fuel cartridge or other objects The fuel cartridge hose is 75 cm long Position the fuel cartridge...

Page 17: ...issible installation angle The inclination of the EFOY fuel cell may not exceed the permissible installation angle Incline along longitudinal axis For continual use 35 Temporary 10 minutes 45 Incline...

Page 18: ...e attached using the belt brackets included in product contents or the optionally available mounting plate 5 1 Attaching the EFOY fuel cell using the belt brackets Measure out the position of the belt...

Page 19: ...elt to the Velcro fastener 5 2 Attaching the EFOY fuel cell using the mounting plate Secure the mounting plate at the required position using countersunk screws 5 mm If necessary use plugs to ensure t...

Page 20: ...alling the EFOY fuel cell Page 20 Tighten the belt Attach the end of the belt to the Velcro fastener 5 3 Fitting the exhaust heat outlet Push the exhaust heat elbow into the exhaust heat outlet connec...

Page 21: ...hicle manufacturer for additional information Push the exhaust heat tube into the exhaust heat elbow Feed the exhaust heat tube through the opening in the exhaust heat guide plate Take care not to kin...

Page 22: ...e side wall To install the exhaust heat tube straight and perpendicular to the side wall cut the exhaust heat elbow 1 at the marking Push the short piece of the exhaust heat elbow into the exhaust hea...

Page 23: ...ked during installation Make sure that the exhaust gas hose is only led sideways or downwards so that any water that may accumulate can drain off Remove the protective cap from the exhaust gas opening...

Page 24: ...fuel cell Page 24 Push the insulated exhaust gas hose onto the exhaust gas opening Drill the opening for the exhaust gas hose A 1 cm Feed the exhaust gas hose from the installation space to outdoors...

Page 25: ...Seal the opening for the exhaust gas hose using sealant Cut the exhaust gas hose as short as possible The external piece may be a maximum of A 5 cm long Cut the end of the exhaust gas hose at an angle...

Page 26: ...ough the fuel cartridge holder Attach the fuel cartridge holder using 4 screws 5 mm If necessary use plugs to ensure that the fuel cartridge holder does not come loose even under heavy load Correctly...

Page 27: ...nics behind the installation opening Use the respective supplied template for drilling and sawing 1 Operating panel 2 Installation opening 3 Screws Pre drill the installation opening 2 Saw out the ins...

Page 28: ...age Two power cables 2 charge the battery The charging cable must be properly assembled before connection DANGER Risk of fire Incorrectly installed or damaged cables may cause a fire Ensure that all c...

Page 29: ...parately where possible so that the current flowing through the power cables does not falsify the measurement of the battery voltage through the sense cables The charging cable can be extended if requ...

Page 30: ...22 0 V 13 0 V 26 0 V Switch off voltage 14 2 V 28 4 V 13 5 V 27 0 V 14 7 V 29 4 V Switch off current 2 0 A 1 0 A 0 5 A 0 25 A 10 0 A 5 0 A Absorption time 180 min 0 min 300 min Capacity 20 Ah 400 Ah...

Page 31: ...ty 20 Ah 600 Ah Max charging duration 48 h 0 h 120 h Min charging duration 30 min 30 min 180 min Switch on delay 300 s 2 s 600 s Battery protection 11 0 V 22 0 V 10 5 V 21 0 V 12 5 V 25 0 V Required s...

Reviews: