The EFOY fuel cell switches on automatically if the charge level drops
below the maximum discharge level (see
S
ECTION
).
Switch-on voltage
Automatic operating mode:
The EFOY fuel cell switches on automatically when the battery voltage
falls below the switch-on voltage (or switch-on threshold) (see
S
ECTION
). The switch-on delay is taken into account here.
Transportation
protection
(EFOY state)
The EFOY fuel cell is delivered with transportation protection activated.
To protect against freezing, there is no water in any critical components.
Settings for the battery and fuel cartridge can be made. Transportation
protection must be deactivated in order to operate the unit.
Transportation
protection procedure
To activate transportation protection, water must be removed from
critical components of the EFOY. This occurs as part of the
transportation protection procedure. Follow the instructions on the
operating panel or app. If the transportation protection procedure has
been completed successfully, the EFOY fuel cell is in the transportation
protection operating phase.