Remedying malfunctions
Page 70
6
Remedying malfunctions
6.1
Malfunctions indicated by messages
In case of interruptions and malfunctions, the status LED will flash or light up (see
S
ECTION
and a message appears in the EFOY app and on the operating panel. There you will find
instructions on how you can remedy the interruption/malfunction.
6.2
Malfunctions not indicated by messages
Error
Possible cause
Remedy
The EFOY fuel cell
does not start
automatically, and
the LED is off.
The battery is connected
incorrectly, defective or fully
discharged.
Check the contacts, polarity
and cable.
Connect a charged battery.
The EFOY fuel cell is in the
Sleep operating mode.
Switch to the Automatic
operating mode.
The operating panel
is not working.
The operating panel is not
connected or is connected
incorrectly.
Check the connection of the
operating panel.
The connection to
the EFOY app is not
working.
The Bluetooth adapter is not
connected or is connected
incorrectly.
Check the connection of the
Bluetooth adapter.
The Bluetooth adapter is no
longer communicating with
the EFOY.
Disconnect the Bluetooth
adapter and connect it again.
If the LED is flashing, a
connection can be
established.
The EFOY fuel cell
repeatedly activates
the battery
protection function.
The battery is damaged, or
too much energy has been
drained.
Check the system.
Change the battery if
necessary.
Should errors occur repeatedly, contact the EFOY hotline.