DEFINITION OF WARNING SIGNS
Risk of machinery breakdown or its operation.
Risk of electrical shock.
1. DESCRIPTION
The
Saniswift® Pro
is a drain pump that is ideally suitable for use in
any section of the house where additional fixtures are needed. It will
pump the gray water away from a variety of sources such as: laundry
sink, washing machine (indirect connection), dishwasher, bar sink, etc.
3. DIMENSIONS
See fig. n°3 page 2.
4. PERFORMANCE CURVE
See fig. n°4 page 2.
2. SPARE PARTS
See fig. n°2 page 2.
5. DISCHARGE HEIGHT
See fig. n°5 page 2.
6. INSTALLATION
This appliance must be installed following our instruction manual and
installation guidelines. It must also be installed in such a way as to en-
sure easy access for repair and maintenance and in accordance with
local plumbing code: CSA B45.9; ASME A112.3.4.
6.1 CONNECTION TO SIDE INLETS
The pump has two side inlets (one on each side) that are meant to
connect additional fixtures. To connect to the side inlets, one rubber
coupling (2” x 2”) is provided along with the clamps. Use this rubber
coupling to connect the side inlet to the PVC pipe coming from
the fixture. An additional rubber coupling (with clamps) will be nee-
ded if you want to use the other side inlet.
6.2 CONNECTION TO INLETS (TOP)
To connect to the top inlets, one rubber coupling (1-1/2” x 1-1/2”) is
provided along with the clamps.
Use this rubber coupling to connect the top inlet to the PVC pipe
which should be from your vent connection.
An additional rubber coupling (with clamps) will be needed if you
want to use the other top inlet. If one of the top inlets is not being
used, a cap is provided to cover this inlet.
6.3 CONNECTION TO A BATHTUB / SHOWER.
When adding a bathtub/shower, a base will have to be constructed.
This base should be made out of a 2” x 6” (minimum) on edge, to
allow for the installation of a P-trap and the required 1/4” per foot
gravity flow towards the pump unit.
6.4 DISCHARGE CONNECTION
The waste water being evacuated by this device must be discharged
using a 1, 1-1/4 or 1-1/2 inch diameter copper or plastic (PVC, CPVC)
pipe. This pump is designed to handle 3/8” particles. The discharge
pipe must be connected to a drain line or sewer line using an appro-
ved “Y” fitting designed for this purpose.
Make sure to only use 1”- 1 1/4” - 1 1/2” rigid pipe for the discharge as
well as 45 degree elbows along installation. Do not use 90 degree
elbows. If long sweeping elbows are not available, use two 45 degree
elbows back-to-back to make a 90 degree turn.
Ensure that the angle of slope is 1/4“ per foot for horizontal drain sec-
tions leading up to the main drain stack to ensure drainage by gravity.
Install an optional full port ball valve at the bottom of the drain pipe
riser to allow shut off in case of repairs.
6.5 CONNECTION TO A VENTILATION SYSTEM
The unit has been designed with a vent connection on the top of
the pump. All plumbing codes require a connection to a vent system.
Connect your vent system using the provided 1-1/2” x 1-1/2” rubber
coupling to connect to your PVC pipe.
DISCONNECT THE POWER SUPPLY BEFORE
ATTEMPTING ANY WORK ON THE DEVICE.
Please note that the vent system should be a two-way air
vent. The use of mechanical vents, air admittance valves or
similar devices are not permitted as these are considered
one-way air vent systems.
6.6 CONNECTION TO THE POWER SUPPLY
CONNECT ONLY TO RECEPTACLE PROTECTED BY A GROUND
FAULT CIRCUIT
WARNING
: RISK OF ELECTRIC SHOCK - THIS PUMP IS SUP-
PLIED WITH GROUNDING CONDUCTOR AND GROUNDING
TYPE ATTACHMENT PLUG. TO REDUCE THE RISK OF
ELECTRICAL SHOCK BE CERTAIN THAT IT IS CONNECTED
ONLY TO A PROPERLY GROUNDED-TYPE RECEPTACLE
All electrical connections must comply with local codes in your re-
gion. The current must be single-phase 110-115 V, 15 A. The electrical
outlet must be located at the minimum distance of 40 inches from
the shower or bath.
Note to only connect this appliance to a ground fault circuit interrup-
ter (GFCI).
7. STANDARDS
This model is eligible to bear the CSA mark shown with adjacent in-
dicators “C” and “US”. The “C” and “US” indicators adjacent to the
CSA mark signify that the product has been tested according to the
applicable CSA (CAN) and ANSI/UL standards for use in Canada and
the USA. This includes products eligible bear the designation NTRL.
NTRL (Nationally Recognized Testing Laboratory) is a designation
awarded by the American Occupational Safety and Health Adminis-
tration (OSHA) to laboratories authorized to award the certification
according to American standards. IAPMO listed for compliance with
the PS 52-2019 standard and the «Uniform Plumbing Code (UPC)».
8. USE
The
Saniswift® Pro
is designed to drain waste water from sinks, was-
hing machines (indirect only), dishwashers, showers and baths.
The
Saniswift® Pro
can pump hot water up to a maximum of 140°F
(60°C), intermittent duty, with ambient température 122°F max
(50°C). If the device operates with water temperatures higher than
specified for a prolonged period, the thermal protector is automati-
cally triggered and the device will cease to pump. In this case, wait
for it to cool down (approximately one hour) so that it automatically
restarts.
Attention
: Never drain cooking grease, alkaline or acidic li-
quids, solvents, paints, oils, or bleaches that may jam or cor-
rode this appliance (consult with us to see what can be
drained).
Note that this pump is not intended to be buried underground instal-
lation and not to be installed in hazardous locations.
9. DISMANTLING
(instructions intended for professionals only)
Disconnect the power supply before attempting
any work on the device.
This device does not require any specific maintenance. In case service
is required, any work on the device must be carried out by a Sani-
flo-approved technician.