 FAULT FINDING

In most cases, any inconsistencies in the operation of the unit will be minor and easy recti-

fied. Please refer to the chart below. If the problem cannot be easily remedied thanks to this 

chart, please call our SFA Service organisation or go to a SFA-approved technician.

FAULT OBSERVED

PROBABLE CAUSES

TROUBLESHOOTING

•  The motor does not work

•  No electricity supply

• Check the control switch

• Check the electrical connections

• Check the power source.

•  The motor works but there is no 

water inlet for flushing

•  The inlet pipe filter is clogged

•  The water inlet pipe is

pinched

•  The through-hull  valve is 

closed

•  The pump is unprimed

 

•  The water injection nozzle /

check valve is clogged

•  The switch is wrongly 

wired up

•  Clean the filter

 •  Check the pipes

 

•  Check the through-hull  valve

 

•  Check the pump and the flexible 

blade turbine  

•  If necessary change the turbine

•  Check the water injection nozzle

•  Check the check valve

•  Check the connection of the 

cables.

•  The motor works but there is 

no outlet

•  The outlet is clogged

•  The outlet is too high

 

•  The through-hull  valve is 

closed

•  There is no water in the bowl

•  The switch is wrongly wired up

• Dismantle and clean the outlet

• Change the outlet 

• Check the pipe routing 

• Check the through-hull  valve

 

• Add water to the bowl

• Check the connection of the 

cables.

•   The motor runs with a rattling 

noise

• A hard foreign body has fallen 

into the bowl

 

• Cut the power supply to the 

motor.

• Close the through-hull  valves

• Remove the motor unit

• Use a hook to remove all

matter that could interfere with the 

rotation of the shredder

• Use a tool to rotate the turbine in

both directions until it turns

freely

• Reconnect the power supply to 

the motor. and press the «Pump 

out» key to check the operation of 

the appliance

• Re-open the through-hull  valves

• If the macerator is still jammed 

we advise you to contact our  

ervice department who will be able 

to advise you or direct you to one 

of our service stations nearest to 

your area.

DISCONNECT THE ELECTRICAL POWER SUPPLY, 

BEFORE ATTEMPTING ANY WORK ON THE UNIT.

UK

13

 GUARANTEE

2 years guarantee from date of purchase, 

subject to correct installation and correct use: 

disposal of toilet papers and fecal matter only. 

Guarantee is limited to replacement or service 

of the defective spare parts, and any indemnity 

or claim for damages will not be included.

Freight and packing costs, travel expenses 

are not included in the guarantee. It does not 

cover any normal deterioration of the material 

over time, any external deterioration or accident, 

incorrect disposal of sanitary products. Any mo-

dification without prior notice will not be under 

guarantee. Fixing, modification, or replacement 

11

 WINTERING

In the event of a long period without use, rinse 

the bowl and carry out several flushing cycles 

with the fresh water and close through-hull val-

ves.

of parts without our agreement will not be gua-

ranted, and will invalidate it. Our liability is solely 

for the product itself.

Guarantee starts from date of purchase we may 

request a copy of the invoice to validate the pur-

chase date.

9

 ELECTRICAL 

CONNECTION

Advice for wiring up the Sanimarin Maxlite:
The maximum recommended voltage drop is 

5% or 0.6V for a supply voltage of 12V, and 

1.2V for a supply voltage of 24V; 
In the event of prolonged absence of supply or 

long absence, cut off the water and electricity 

supplies to the Maxlite.

Electricity consumption per second:

 

12V : 0.007 Ah

24V : 0.004 Ah

Current consumption / Fuses:

12V : 300 W  / 25 A

24V : 360 W / 15 A

Electric diameter wire:

12V (300 W)

1.5mm² =  1M  max

2.5mm² =  2M  max

4mm²   =  3M max

6mm²  =  4,3M max
24V (360W)

1.5mm² =  3,5M  max

2.5mm² =  6M  max

4mm²   =  9,5M max

6mm²  =  14M max

10

 Cleaning / descaling

For cleaning, use normal sanitary products.

CAUTION:

 

• Do not use aggressive chemicals (such as 

acetone, pure bleach, etc.) that could da-

mage the material of the bowl.

• Use a suitable standard toilet brush; do 

not use scouring or abrasive pads.

Summary of Contents for MAXLITE

Page 1: ...ALLATION INSTRUCTIONS DE INSTALLATIONSHINWEISE IT STRUZIONI PER L INSTALLAZIONE ES MANUAL DE INSTALACIÓN DK INSTALLATIONSVEJLEDNING NO INSTALLASJONSANVISING FI ASENNUSOHJEET RU ИНСТРУКЦИЯ ПО МОНТАЖУ И ЭКСПЛУАТАЦИИ TR KURULUM KILAVUZU 708 11 15 MAXLITE ...

Page 2: ...1 B x1 C x3 D x3 E x1 F x1 J x4 G x2 H x1 12V 25A 24V 15A FUSE x3 356 460 350 296 283 377 50 91 417 350 146 225 110 417 460 417 460 356 460 350 296 283 377 50 91 41 350 14 225 110 417 460 Ø 20x32 Ø 27 Ø 17 5 Ø 32x55 ...

Page 3: ...OR 1 2 3 4 Ø 25mm int Ø 38mm int Ø 20mm int D B A D E C OR 30 ...

Page 4: ...5 6 x4 6 6b 0 3m mini E C G ...

Page 5: ...6 7 0 5m mini 1 1 2 4 5 2 3 6 1 2 3 6 1 2 4 5 Hand pump toilet replacement ...

Page 6: ... BAT BAT MOT MOT 8 F G ...

Page 7: ...1 2 6 5 3 29 27 28 27 20 21 22 18 17 4 16 15 14 13 10 9 26 7B 11 8 45 31 7 32 26 19 12 29b ...

Page 8: ...110 mm 225 mm 70 mm 110 mm SCALE 1 1 ...

Page 9: ......

Page 10: ...SFA SANIBROY GmbH Waldstr 23 Geb B5 63128 Dietzenbach Tel 060 74 30928 0 Fax 060 74 30928 90 ITALIA SFA ITALIA spa Via del Benessere 9 27010 Siziano PV Tel 03 82 61 81 Fax 03 82 61 8200 ESPAÑA SFA S L C Vinyalets 1 P I Can Vinyalets 08130 Sta Perpètua de Mogoda Barcelona Tel 34 93 544 60 76 Fax 34 93 462 18 96 PORTUGAL SFA Lda Sintra Business Park ed 01 1ºP2710 089 SINTRA Tel 35 21 911 27 85 Fax 3...

Page 11: ...2 En cas de coupure de courant prolongée ou de longue absence couper les alimentations en eau et électricité du Maxlite ATTENTION 3 Avant de commencer tout travail sur ce produit assurez vous que toute alimen tation électrique de l unité a été éteinte et que les vannes passe coque sont en position FERME ou ARRET 6 FIXATION DE L APPAREIL Fixez solidement le Maxlite à l aide des vis pré vues à cet e...

Page 12: ...teliers des pièces re connues défectueuses En aucun cas la garantie n impliquelapossibilitéd unedemandededom mages et intérêts ou d indemnité Les frais de port et d emballage les frais de dé placement ne sont pas couverts par notre ga rantie La garantie ne s applique pas au rempla cement ou aux réparations qui résulteraient de l usure normale du matériel de détérioration ou d accident provenant de...

Page 13: ... electrical power to the unit has been switched off and that the through hull valves are in the CLOSED or STOP position 6 FIXINGTHE DEVICE Fix the Maxlite securely using the screws pro vided The Maxlite can be installed in place of a toilet with a manual pump Your mountings must be appropriate for the base on which the device is to be installed You can turn the Maxlite s bowl to suit your requirem...

Page 14: ... ervice department who will be able to advise you or direct you to one of our service stations nearest to your area DISCONNECT THE ELECTRICAL POWER SUPPLY BEFORE ATTEMPTING ANY WORK ON THE UNIT UK 13 GUARANTEE 2 years guarantee from date of purchase subject to correct installation and correct use disposal of toilet papers and fecal matter only Guarantee is limited to replacement or service of the ...

Reviews: