Product dimensions
Noise level
The noise level depends on the fitting conditions and operating point.
This sound pressure level Lp is less than 70 dB (A).
3.5 Pumped fluids
WARNING
Pumping unauthorised fluids.
Dangerous for people and the environment!
➜
Only discharge authorised pumped fluids into the public sewerage
network.
Authorised pumped fluids:
The following liquids are allowed in discharge systems:
• Water contaminated by domestic use, human excrement, toilet roll.
Unauthorised pumped fluids:
The following liquids and substances are banned:
• Solid materials, fibres, tar, sand, cement, ash, coarse paper, hand towels, wipes, cardboard,
rubble, rubbish, slaughterhouse waste, oils, hydrocarbons, greases, etc.
• Wastewater containing harmful substances (for example, untreated greasy waste from restaurants).
Pumping these liquids and substances requires the fitting of a compliant grease trap.
• Rain water.
3.6 Installation of the SANIPUMP pumping station
®
• The characteristics shown on the rating plate have been compared with those on the order and
installation (supply voltage, frequency).
• The SANIPUMP
®
pumping station cannot be immersed in water more than 5 m deep.
• The minimum height of the entries into the sump must be 500 mm with respect to the bottom of the
manhole.
• The installation room must be protected against frost.
190
76,7
264
400
190
281
90
424
G 1-1/4 for SANIPUMP
®
macerator
G 2 for SANIPUMP
®
vortex
SANIPUMP
®
macerator SANIPUMP
®
vortex