30
5.2.6 Interleaved 2 of 5
Restore Factory Defaults
Restore the Factory Defaults of Interleaved 2 of 5
Enable/Disable Interleaved 2 of 5
Enable Interleaved 2 of 5
*Disable Interleaved 2 of 5
Message Length
Message length can be set to the maximum value, minimum value. The data between the maximum and the
minimum is valid.
The maximum value and minimum value can be set using Programming Command. Please check the
programming command guide for the detail.
Interleaved 2 of 5 max length command: 020404. The parameter of this command can be set from min to 80.
Interleaved 2 of 5 min length command: 020403. The parameter of this command can be set from 2 to max.
Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25.
Programming command
Max: 02040425.
Min: 02040310.
Interleaved 2 of 5 Check Digit
No check Char
*Validate and Transmit
Validate not Transmit
Summary of Contents for BD-6500BT
Page 1: ...BD 6500BT Bluetooth 2D Barcode Scanner Configuration Guide V 2 1...
Page 11: ...10 Slovakia Slovenia Spain Sweden Swiss French Swiss German Turkey F Turkey Q UK Japan...
Page 15: ...14 3 6 Beeper Duration Good Read Normal Short 3 7 Beeper Number Good Read 1 2 3 4 5 6...
Page 16: ...15 3 8 Barcode Scanning Delay No Delay Delay 500ms Delay 2000ms...
Page 17: ...16 4 Data Formatting 4 1 General Configuration Add CR Add LF Add CR LF Add TAB...
Page 20: ...19 5 Symbologies 5 1 General Settings Enable All Symbologies...
Page 55: ...54 6 2 Appendix 2 Digit Barcodes 0 1 2 3 4 5 6 7 8 9 A B C D E F...