20
5.2 1D Symbologies
5.2.1
Code 128
Restore Factory Defaults
Restore the Factory Defaults of Code 128
Enable/Disable Code 128
* Enable Code 128
Disable Code 128
Message Length
Message length can be set to the maximum value or minimum value. The value between the maximum and
the minimum is valid.
The maximum value and minimum value can be set using
“Programming Command”. Please check the
programming command guide for the detail.
Code 128 max length command: 020A03. The parameter of this command can be set from min to 90.
Code 128 min length command: 020A02. The parameter of this command can be set from 0 to max.
Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25.
Programming command:
Max: 020A0325.
Min: 020A0210.