background image

- 9 - 

 

                                 

 

    Start configuration                                            End configuration 

 

ITEM 

OPTION 

 

* Disable 

Caps Lock   

 

Enable 

 

* Disable 

Num Lock 

 

Enable 

 

Inter Character Delay 

(Default

00) 

Ref: Appendix

00—64H

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for BC-5000

Page 1: ... 1 BARCODE SCANNER Configuration Guide ...

Page 2: ...nning mode selection 16 2 3 Beeper tone selection 17 2 4 String Options Prefix Suffix 18 2 5 Setup Insertion 19 Chapter 3 BarCode parameters setting 3 1 UPC A 23 3 2 UPC E 26 3 3 EAN 13 29 3 4 EAN 8 31 3 5 Code39 33 3 6 Codabar 36 3 7 Code93 40 3 8 Code128 42 3 9 Interleaved2 of 5 45 3 10 Industrial 2of 5 47 3 11 Matrix 2 of 5 49 3 12 China Postage 51 3 13 MSI Plessey 53 3 14 Code 32 55 3 15 Code ...

Page 3: ...change these settings programming is accomplished by scanning the bar codes in this guide 1 2 How to set up the parameter I 1 Scan Start Configuration 2 Scan all necessary labels for parameters that meet your applications 3 Scan End Configuration to end the programming Start configuration End configuration Standard Product Defaults Setting Check Version An asterisk next to an option indicate the d...

Page 4: ...le reads are needed to complete the configuration When use these special parameters In some cases you might need to read one or more barcodes such as Hexadecimal barcodes For example prefix suffix etc Numeric barcodes For example inter character delay max min length To complete the change of setting you will need to read the Confirm barcode after you read the parameter Below is the flow chart to e...

Page 5: ...esetting is requested for USB interface Scanning USB bar code after the cable is changed and activating the scanner by plugging the USB cable again USB interface complies with HID keyboard which means the setting of USB scanner is exactly the same like the default setting from keyboard Start configuration End configuration ITEM OPTION KEYBOARD RS 232 USB Interface Selection USB COM ...

Page 6: ...1 Keyboard emulation parameters setting Start configuration End configuration ITEM OPTION IBM AT IBM XT IBM PS 2 30 80 IBM 5550 PS 2 25 30 NEC 9801 Reserved 1 Device Selection for keyboard Interface Reserved 2 ...

Page 7: ... 7 Start configuration End configuration ITEM OPTION USA ITALIAN SPANISH FRENCH GERMAN JAPANESE Multi Language Support Language for Keyboard Interface Reserved 1 ...

Page 8: ...nction Key Enable Disable Emulate External Keyboard Enable Disable ALT Mode Enable NOTE Emulate External Keyboard Scan the barcode below if you do not have an external keyboard After scanning the Emulate External Keyboard bar code you must power cycle your computer ...

Page 9: ... 9 Start configuration End configuration ITEM OPTION Disable Caps Lock Enable Disable Num Lock Enable Inter Character Delay Default 00 Ref Appendix 00 64H ...

Page 10: ...10 Start configuration End configuration ITEM OPTION None CR Tab ESC Terminator CR LF Block transmission delay Default 00 Ref Appendix 00 0AH Keyboard Speed Default 00 high clock rate Ref Appendix 00 08H ...

Page 11: ... 11 2 1 2 RS 232 communication setting Start configuration End configuration ITEM OPTION 1200bps 2400bps 4800bps 9600bps 19200bps Baud Rate 38400bps 7 Bits Data Bits 8 Bits ...

Page 12: ... 12 Start configuration End configuration ITEM OPTION 1 Stop Bits Stop Bits 2 Stop Bits NONE ODD EVEN Mark Parity Space ...

Page 13: ...End configuration ITEM OPTION Inter character delay Default 00 Ref Appendix 00 64H Block transmission delay Default 00 Ref Appendix 00 0AH Response delay Default 00 Ref Appendix 00 0AH None RTS CTS ACK NAK HANSHAKING Xon Xoff ...

Page 14: ... 14 Start configuration End configuration ITEM OPTION None CR LF CR LF Tab STX ETX Terminator For RS 232 EOT ...

Page 15: ... 15 Start configuration End configuration ITEM OPTION None RTS CTS ACK NAK Handshaking Xon Xoff ...

Page 16: ...lection Start configuration End configuration ITEM OPTION Trigger On Good Read Off Trigger On Off Continuous Trigger Off Continuous Testing Continuous Trigger on Continuous Auto power on Flash Reading Mode Flash Auto Power On ...

Page 17: ...Beeper tone selection Start configuration End configuration ITEM OPTION Beep Tone Default 09H Ref Appendix 00 10H Beep Sound Duration Default 05H Ref Appendix 00 10H Enable Power On Beeper Disable ON Beeper OFF ...

Page 18: ...at Prefix Code ID Bar Code Suffix How to set up a prefix To configure as prefix 1 Scan Start Configuration barcode 2 Scan Preamble bar code 3 Scan twice from FULL ASCII table 4 Scan Confirm configuration barcode 5 Scan End Configuration barcode How to set up a suffix To configure as suffix 1 Start configuration barcode 2 Scan Postamble barcode 3 Scan twice from FULL ASCII table 4 Scan Confirm conf...

Page 19: ... This section describes how to setup the insertion of output NOTE Max 10 charters can be inserted each time Max Insertion group is only two Insertion group 01 or 02 can be used in different kinds of barcodes at the same time ...

Page 20: ...ou wish to place the character 6 Scan Start Configuration barcode 7 Scan G1 Character Position 8 Scan 0 and 3 from FULL ASCII Table which presents the position 9 Scan Confirm configuration barcode 10 Scan End configuration barcode How to set up insertion for code 39 Go to chapter 3 5 code 39 11 Scan Start Configuration barcode 12 Scan Insert group selection bar code 13 scan 0 and 1 from FULL ASCII...

Page 21: ...eamble Default 00 Ref Appendix Postamble Default 00 Ref Appendix G1 Insertion character Default 00 Ref Appendix G2 Insertion character Default 00 Ref Appendix G1 Character Position to be inserted Default 00 Ref Appendix G2 Character Position to be inserted Default 00 Ref Appendix ...

Page 22: ... Read 1 Time Accuracy Read 2 Times Bar equals high Reading Bar equals low Code Type ID Code Type ID UPC A F Interleaved 25 N UPC E G Industrial 25 O EAN 13 H Matrix 25 P EAN 8 I China Postal Code Q Code 39 J MSI Plessey R Codabar K Code 32 S Code 93 L Code 11 T Code 128 M Telepen V ...

Page 23: ... to the ASCII Table and scan label that represent the desired characters to be inserted 3 Scan Confirm configuration bar code 4 Scan End configuration bar code Start configuration End configuration Confirm configuration 3 1 UPC A ITEM OPTION Disable Read Enable Code ID Setting Default F Ref Appendix 20 7EH ...

Page 24: ...PTION Disable UPC A Expand to EAN 13 Enable Disable Check Digit Send Enable Disable Truncate Leading Zero Enable Truncate Leading Default 00 Ref Appendix 00 0DH Truncate Ending Default 00 Ref Appendix 00 0DH Insert group selection Ref Appendix 00 02H ...

Page 25: ... 25 Start configuration End configuration ITEM OPTION NONE 2 digits 5 digits 2 or 5digits Supplement digits Auto discriminate Supplement ...

Page 26: ... 26 3 2 UPC E Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default G Ref Appendix 20 7EH ...

Page 27: ...ration ITEM OPTION Disable UPC E Expand to UPC A Enable Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00 08H Truncate Ending Default 00 Ref Appendix 00 08H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 28: ... 28 Start configuration End configuration ITEM OPTION Disable Truncate Leading Zero Enable None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement ...

Page 29: ...ration End configuration ITEM OPTION Disable Read Enable Code ID setting Default H Ref Appendix 20 7EH Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00 0DH Truncate Ending Default 00 Ref Appendix 00 0DH ...

Page 30: ...figuration End configuration ITEM OPTION None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement Disable ISBN ISSN Conversion Enable Insert group selection Default 00 Ref Appendix 00 02H ...

Page 31: ...3 4 EAN 8 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default I Ref Appendix 20 7EH Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00 08H ...

Page 32: ...ation End configuration ITEM OPTION Truncate Ending Default 00 Ref Appendix 00 08H None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement Insert group selection Default 00 Ref Appendix 00 02H ...

Page 33: ...3 3 5 Code39 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default J Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmission Enable ...

Page 34: ...tart configuration End configuration ITEM OPTION Disable Append Enable Min code length Default 00 Ref Appendix 00 32H Max code length Default 32H Ref Appendix 00 32H Standard Code39 Format Code 39 Full ASCII ...

Page 35: ...n End configuration ITEM OPTION Disable Transmit Start End Character Enable Truncate Leading Default 00 Ref Appendix 00 32H Truncate Ending Default 00 Ref Appendix 00 32H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 36: ... 36 3 6 Codabar Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default K Ref Appendix 20 7EH ...

Page 37: ... 37 Start configuration End configuration ITEM OPTION Disable Check sum verification Enable Disable Check sum transmission Enable Disable Append Enable Truncate Leading Default 00 Ref Appendix 00 7EH ...

Page 38: ...iguration End configuration ITEM OPTION Truncate Ending Default 00 Ref Appendix 00 7EH ABCD ABCD abcd abcd Start End type abcd tn e Disable Start End transmission Enable Min code length Default 05 Ref Appendix 00 3CH ...

Page 39: ... 39 Start configuration End configuration ITEM OPTION Max code length Default 3CH Ref Appendix 00 3CH Insert group selection Default 00 Ref Appendix 00 02H ...

Page 40: ... 40 3 7 Code93 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default L Ref Appendix 20 7EH Disable Check sum verification Enable ...

Page 41: ...e Check sum transmission Enable Min code length Default 00 Ref Appendix 0 50H Max code length Default 50H Ref Appendix 0 50H Truncate Leading Default 00 Ref Appendix 00 7EH Truncate Ending Default 00 Ref Appendix 00 7EH Insert group selection Ref Appendix 00 02H ...

Page 42: ... 42 3 8 Code 128 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default M Ref Appendix 20 7EH Disable Check sum verification Enable ...

Page 43: ... 43 Start configuration End configuration ITEM OPTION Disable Check sum transmission Enable Disable FNC2 Append Enable Disable UCC EAN128 Enable Disable FNC1 transmission Enable ...

Page 44: ...PTION Truncate Leading Default 00 Ref Appendix 00 7FH Truncate Ending Default 00 Ref Appendix 00 7FH Min code length Default 00 Ref Appendix 00 7FH Max code length Default 7FH Ref Appendix 00 7FH Insert group selection Default 00 Ref Appendix 00 02H ...

Page 45: ...Interleaved 2 of 5 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default N Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmission Enable ...

Page 46: ...PTION Truncate Leading Default 00 Ref Appendix 00 7EH Truncate Ending Default 00 Ref Appendix 00 7EH Min code length Default 00 Ref Appendix 00 7FH Max code length Default 7FH Ref Appendix 00 7FH Insert group selection Default 00 Ref Appendix 00 02H ...

Page 47: ...l 2 of 5 Start configuration End configuration ITEM OPTICON Disable Read Enable Code ID setting Default O Ref Appendix 20 7EH Min code length Default 00 Ref Appendix 00 32H Max code length Default 32H Ref Appendix 00 32H ...

Page 48: ...ion ITEM OPTION Truncate Leading Default 00 Ref Appendix 00 32H Truncate Ending Default 00 Ref Appendix 00 32H Disable Check sum verification Enable Disable Check sum transmission Enable Insert group selection Default 00 Ref Appendix 00 02H ...

Page 49: ... 49 3 11 Matrix 2 of 5 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default P Ref Appendix 20 7EH Disable Check sum verification Enable ...

Page 50: ... sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 0B Ref Appendix 00 50H Max code length Default 50H Ref Appendix 00 50H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 51: ... CHINA POSTAL CODE Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default Q Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmission Enable ...

Page 52: ...PTION Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 00 Ref Appendix 00 50H Max code length Default 50H Ref Appendix 00 50H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 53: ... 53 3 13 MSI Plessey Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default R Ref Appendix 20 7EH Disable MOD 10 MOD 10 10 Check sum verification MOD 11 10 ...

Page 54: ... sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 3CH Truncate Ending Default 00 Ref Appendix 00 3CH Min code length Default 00 Ref Appendix 00 3CH Max code length Default 3CH Ref Appendix 00 3CH Insert group selection Default 00 Ref Appendix 00 02H ...

Page 55: ... 32 Italian Pharma Code Start configuration End configuration ITEM OPTION Disable Read Enable Code ID Setting Default S Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmission Enable ...

Page 56: ... 56 Start configuration End configuration ITEM OPTION Truncate Leading Default 00 Ref Appendix 00 0AH Truncate Ending Default 00 Ref Appendix 00 0AH Insert group selection Default 00 Ref Appendix 00 02H ...

Page 57: ... 57 3 15 CODE 11 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default T Ref Appendix 20 7EH Disable Check sum verification Enable ...

Page 58: ... sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 00 Ref Appendix 00 50H Max code length Default 50H Ref Appendix 00 50H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 59: ...9 3 16 Telepen Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default V Ref Appendix 20 7EH Disable Check sum verification Enable Only Numnic Data Format Full ASCII ...

Page 60: ... sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 40H Truncate Ending Default 00 Ref Appendix 00 40H Min code length Default 00 Ref Appendix 00 40H Max code length Default 40H Ref Appendix 00 40H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 61: ... 61 3 17 GS1 Data Bar RSS Start configuration End configuration ITEM OPTION Enable RSS 14 Disable Enable RSS 14 LIMITED Disable Enable RSS 14 EXPANDED Disable Enable RSS TO UPC EAN Disable ...

Page 62: ...ON Disable Function Key Enable Code 39 format Full ASCII Code 39 To scan a function key barcode label Full ASCII Code 39 must be enabling Please refer to Full ASCII Code 39 Table to produce the function key barcode label Function Code UP A F1 Q DOWN B F2 R LEFT C F3 S RIGHT D F4 T ...

Page 63: ... 63 PAGE UP E F5 U PAGE DOWN F F6 V BS H F7 W TAB I F8 X HOME K F9 Y END L F10 Z ENTER M ESC A INSERT N F11 B DELETE O F12 C ...

Page 64: ... 64 Appendix A ...

Page 65: ...9 HT 41 29 10 0A LF 42 2A 11 0B VT 43 2B 12 0C FF 44 2C 13 0D CR 45 2D 14 0E SO 46 2E 15 0F SI 47 2F 16 10 DLE 48 30 0 17 11 DC1 49 31 1 18 12 DC2 50 32 2 19 13 DC3 51 33 3 20 14 DC4 52 34 4 21 15 NAK 53 35 5 22 16 SYN 54 36 6 23 17 ETB 55 37 7 24 18 CAN 56 38 8 25 19 EM 57 39 9 26 1A SUB 58 3A 27 1B ESC 59 3B 28 1C FS 60 3C 29 1D GS 61 3D 30 1E RS 62 3E 31 1F US 63 3F ...

Page 66: ...73 49 I 105 69 i 74 4A J 106 6A j 75 4B K 107 6B k 76 4C L 108 6C l 77 4D M 109 6D m 78 4E N 110 6E n 79 4F O 111 6F o 80 50 P 112 70 P 81 51 Q 113 71 q 82 52 R 114 72 r 83 53 S 115 73 s 84 54 T 116 74 t 85 55 U 117 75 u 86 56 V 118 76 v 87 57 W 119 77 w 88 58 X 120 78 x 89 59 Y 121 79 y 90 5A Z 122 7A z 91 5B 123 7B 92 5C 124 7C 93 5D 125 7D 94 5E 126 7E 95 5F _ 127 7F DEL ...

Page 67: ... 67 Table Hex HEXADCIMAL Confirm configuration End Configuration ...

Page 68: ... 68 Function Key Table 0 1 0 NULL 1 UP F1 2 DOWN F2 3 LEFT F3 4 RIGHT F4 5 PAGE UP F5 6 PAGE DOWN F6 7 F7 8 BS F8 9 TAB F9 A F10 B HOME ESC C END F11 D ENTER F12 E INSERT F DELETE ...

Page 69: ... 69 DEFAULT CHECK VERSION Version 3 1 ...

Reviews: