21
20
9-5. Environmental Requirements
(1) Operating
Temperature
0°C to 45°C
Humidity
10% to 90% RH (without condensation)
(2) Transport/Storage (except paper)
Temperature
-20°C to 60°C
Humidity
10% to 90% RH (without condensation)
9-6. Reliability
(1) MCBF
50 million lines (based on an average printing rate of 12.5% with paper
thickness in the range 65µm to 75µm)
35 million lines (based on an average printing rate of 12.5% with paper
thickness in the range 76µm to 150µm)
(2) Head Life
100 million pulses, 150Km
(3) Cutter Life
1.8 million cuttings (if the paper thickness is between 65 and 80mm)
9-7. Certification
(1) FCC PART15 CLASS A
(2) UL/cUL (UL 60950-1)
(3) KC
(4) CE-EMCD (CE-EMCD Class B should use Parallel shield Cable complied with IEEE-1284 standards)
(5) ENERGY STAR
No.
Command
Function
REMARKS
1
HT
Horizontal tab
2
LF
Print and line feed
3
CR
Print and carriage return
4
FF
Print and return to standard mode(in page mode)
5
CAN
Cancel print data in page mode
6
DLE EOT
Real-time status transmission
7
DLE ENQ
Real-time request to printer
8
DLE DC4
Generate pulse at real-time
9
ESC FF
Print data in page mode
10
ESC SP
Set right-side character spacing
11
ESC !
Select print mode(s)
12
ESC $
Set absolute print position
13
ESC %
Select/cancel user-defined character set
14
ESC &
Define user-defined characters
15
ESC *
Set bit-image mode
16
ESC -
Turn underline mode on/off
17
ESC 2
Select default line spacing
18
ESC 3
Set line spacing
19
ESC =
Select peripheral device
20
ESC ?
Cancel user-defined characters
21
ESC @
Initialize printer
22
ESC D
Set horizontal tab positions
23
ESC E
Turn emphasized mode on/off
24
ESC G
Turn double-strike mode on/off
25
ESC J
Print and feed paper using minimum units
26
ESC L
Select page mode
27
ESC M
Select character font
28
ESC R
Select an international character set
29
ESC S
Select standard mode
30
ESC T
Select print direction in page mode
31
ESC V
Turn 90° clockwise rotation mode on/off
32
ESC W
Set printing area in page mode
33
ESC
\
Set relative print position
34
ESC a
Select justification
35
ESC c 3
Select paper sensor(s) to output paper-end signals
36
ESC c 4
Select paper sensor(s) to stop printing
37
ESC c 5
Enable/disable panel buttons
38
ESC d
Print and feed paper n lines
39
ESC p
General pulse
10. Command List
This equipment is indoor use and all the communication wirings are limited to inside of the building.