- 24 -
SI 510 WEIGHING INDICATOR
156
External Digital Input 1
01
00: Disuse
01: Run
02: Stop
03: Complete BIN with enforce
04: Reset BATCH
05: Make Zero
157
External Digital Input 2
02
158
External Digital Input 3
03
159
External Digital Input 4
04
160
External Digital Input 5
05
161
External Digital Input 6
00
Communication Setting
200
Port 1 Parity / Stop bit
00
00: Data bit8, Stop bit1, Parity bit Non
01: Data bit8, Stop bit1, Parity bit Odd
02: Data bit8, Stop bit1, Parity bit Even
03: Data bit7, Stop bit1, Parity bit Non
04: Data bit7, Stop bit, Parity bit Even
201
Port 1 Communication Speed
02
00 : 2,400bps
01 : 4,800bps
02 : 9,600bps
03 : 14,400bps
04 : 19,200bps
05 : 28,800bps
06 : 38,400bps
07 : 57,600bps
08 : 76,800bps
09 : 115,200bps
202
Port 1 Communication Mode
00
00 : Simplex / Stream Mode
01 : Duplex / SI4500 Command Mode
02 : Duplex / SI550 Command Mode
03 : Print Mode
04 : Modbus (RTU)
203
Port 1 Simplex / Stream Mode
Protocol
00
00 : Format 1 (19byte)
01 : Format 2 (22byte)
02 : Format 3 (17byte)
03 : Format 4 (22byte)
204
Port 1 Date transference under
stream mode
00
00 : Countinuously
01 : Single time on every steady state
02 : Single time at the first steady point
03 : Single time output after weighing finish
04 : When input Print key
205
Port 1 Command "Check-Sum"
Setting
00
00 : Disuse
01 : Use
206
Port 1 Modbus Transmit Data
SWAP
00
00 : Standard
01 : Change