20
│ 5 Appendix
Detection
Transmitting frequency
• direct energizing:
512 Hz / 640 Hz / 1.100 kHz / 8.192 kHz /
9.950 kHz / 32.768 kHz / 41.666 kHz /
65.536 kHz / 83.078 kHz / 116.000 kHz
can also be set to any frequency between
200 Hz - 116.000 kHz.
• indirect energizing:
9.950 kHz / 41.666 kHz
Transmitting power
• with continuous signal: 25 W
• with pulsed signal:
50 W
Transmitting current
• with continuous signal: 0.5 A
• with pulsed signal:
1 A
Transmission voltage,
effective
max. 120
V
5.2
Preset frequencies
Frequency
Display in
Frequency list
Main view
512 Hz
512 Hz
512 Hz
640 Hz
640 Hz
640 Hz
1.100 kHz
1100 Hz
1,10 kHz
8.192 kHz
8192 Hz
8,19 kHz
9.950 kHz*
9950 Hz
9,95 kHz
32.768 kHz
32768 Hz
32,8 kHz
41.666 kHz*
41666 Hz
41,7 kHz
65.536 kHz
65536 Hz
65,5 kHz
93.078 kHz
93078 Hz
93,1 kHz
116.000 kHz
116000 Hz
116 kHz
* For direct as well as indirect energizing.