3 Energizing a pipeline
│
9
3.2
Setting the frequency
3.2.1
Selecting the frequency
The frequency for energizing must always be adapted to the
local conditions.
Note:
The generator and receiver must operate at the same frequency.
●
Adjust the frequency of the receiver to the frequency of the
generator.
The generator is switched on. The display shows the main
view.
●
Press one of the frequency keys repeatedly until the desired
frequency is displayed.
3.2.2
Activating and deactivating frequencies
The factory setting is that all preset frequencies are activated.
Activated frequencies can be selected in the main view using
frequency keys.
Note:
The frequencies for indirect energizing cannot be deactivated.
The generator is switched off.
1. Open the
PIN-Code
view (fig. 6).
● Simultaneously press both frequency keys and the On/Off
key until the
PIN-Code
view appears.
2. Enter the PIN code
0001
.
●
Press the arrow keys to move the cursor right or left.
●
Press the frequency keys to increase or decrease the digits.
● Press the On/Off key to complete the PIN code entry.
The
Frequency list 1
view (fig. 5, left image) appears.