Fig. 18 shows control word 2 for the MOVITRAC
®
31.. inverter without digital input terminal
expansion, e.g. when the
FEN Speed Measurement option is fitted. As no optional physical input
terminals are available, these can be mapped completely to the virtual terminals of the fieldbus.
You can program any function to the virtual input terminals. The following table shows the virtual
input terminal assignment for the MOVITRAC
®
31.. inverter without digital input terminal expansion
and their functionality.
Virtual
input terminal
Assigned
to terminal
Functionality
1
48
Terminal function programmable to
P603 TERMINAL 48
2
49
Terminal function programmable to
P604 TERMINAL 49
3
50
Terminal function programmable to
P605 TERMINAL 50
4
51
Terminal function programmable to
P606 TERMINAL 51
5
52
Terminal function programmable to
P607 TERMINAL 52
6
53
Terminal function programmable to
P608 TERMINAL 53
7
54
Terminal function programmable to
P609 TERMINAL 54
8
–
None
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
9: Virtual terminal 2 =
terminal 49
15: Virtual terminal 8
reserved
MOVITRAC 31..
digital input terminal expansion
®
without
0: Controller inhibit/enable
1: Enable/rapid stop
3: Hold control
4: Ramp generator selection
6: Reset
5: Parameter set selection
7: Reserved
2: Enable/stop
Permanently defined
Virtual input terminals
8: Virtual terminal 1 =
terminal 48
10: Virtual terminal 3
= terminal 50
11: Virtual terminal 4
= terminal 51
12: Virtual terminal 5 =
terminal 52
13: Virtual terminal 6
= terminal 53
14: Virtual terminal 7
= terminal 54
00328AEN
Fig. 18: Control word 2 for MOVITRAC
®
31.. without digital input terminal expansion
Inverter Control
with Process Data
3
32
MOVITRAC
®
31.. Fieldbus Unit Profile