841 FIELDBUS
CONTROL MODE
no function
no function
1/0 CW/STOP
+24 V
Program functionality of input terminal 43 to NO FUNCTION in parameter P601.
5. Input terminal 43 = NO FUNCTION:
Program functionality of input terminal 42 to NO FUNCTION in parameter P600.
4. Input terminal 42 = NO FUNCTION:
Set control and setpoint processing of the drive inverter to FIELDBUS in parameter P841.
3. Control mode = fieldbus
2. For setting inverter parameter only switch on 24 V supply (no mains voltage!)
Apply a +24 V signal on input terminal 41 (Function CW/STOP) (e.g. set jumper as shown below).
1. ENABLE the inverter on the terminal side
601 NO FUNCT.
TERMINAL 43
600 NO FUNCT.
TERMINAL 42
Size 0
Size 1 - 4
Jumper installed when supplied
Use this jumper to enable the
inverter via terminal side
no function
no function
1/0 CW/STOP
Jumper installed when supplied
Use this jumper to enable the
inverter via terminal side
00312BEN
Fig. 2: Activating the FIELDBUS control mode
Inverter Control
with Process Data
3
10
MOVITRAC
®
31.. Fieldbus Unit Profile