SEW 6213A-IN User Manual Download Page 6

Medidores de aislamiento - Megohmetros Digitales VDC GigaOhmios 6213-IN SEW manual ingles www.viaindustrial.com

 

 

Medidores de aislamiento - Megohmetros Digitales VDC GigaOhmios 6213-IN SEW manual ingles www.viaindustrial.com

 

 

 

SAFETY  CHECK

 

Before

 

using

 

the

 

tester

 

check

 

the

 

condition

 

of

 

the

 

test

 

leads

 

and

 

the

 

fuses.

 

If

 

using

 

fused

 

test

 

leads.

 

 

The

 

test

 

leads

 

must

 

be

 

free

 

of

 

cracks

 

or

 

any

 

damages

 

and

 

must

 

be

 

insulated

 

as

 

when

 

they

 

were

 

new.

 

 

Always

 

disconnect

 

the

 

test

 

leads

 

when

 

changing

 

the

 

batteries

 

by

 

removing

 

the

 

cover

 

which

 

give

 

access

 

to

 

the

 

batteries.

 

 

Always

 

double

 

check

 

the

 

lead

 

connections

 

before

 

making

 

any

 

measurements.

 

For

 

increased

 

safety,

 

use

 

fused

 

test

 

leads

 

(optional).

 

 
 
 
 

 

DON'T  TOUCH

 

Don't

 

touch

 

exposed

 

wiring,

 

connections

 

or

 

other

 

"Live"

 

parts

 

of

 

an

 

electrical

 

circuit.

 

If

 

in

 

doubt,

 

check

 

the

 

circuit

 

first

 

for

 

voltage

 

before

 

touching

 

it.

 

 

Do

 

not

 

use

 

cracked

 

of

 

broken

 

test

 

leads.

 

 

THIS

 

INSTRUMENT

 

SHOULD

 

ONLY

 

BE

 

USED

 

BY

 

A

 

COMPETENT,

 

SUITABLY

 

TRAINED

 

PERSON.

 

 

REMEMBER

 

 

SAFETY

 

IS

 

NO

 

ACCIDENT

 

 
 

CAUTION

 

RISK

 

OF

 

ELECTRIC

 

SHOCK

 

 
 

CAUTION

 

READ

 

THE

 

MANUAL

 

 
 

-6-

 

Summary of Contents for 6213A-IN

Page 1: ...itales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com Medidores de aislamiento Megohmetros Digitales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com 6213A IN DIGITAL VAR...

Page 2: ...ingles www viaindustrial com TABLE OF CONTENTS Index 2 Front Panel Layout 3 Inside Lid Instructions 4 Safety precautions 5 8 Overview 9 Features 10 Connections 11 Specifications 12 Functions 13 15 Sp...

Page 3: ...AYSREADUSER SMANUALBEFOREOPERATINGTHISINSTRUMENT Useonlyonde energisedandisolated disconnectedsystem DONOTPROCEEDIFVOLTAGEPRESENT Checktestleadsfordefects Ifanycracksordamages replacewithnewtest leads...

Page 4: ...AR WARNING Thisinstrumentshould notbeusedinexplosive orinflammable environments although thereisunlikelytobea firehazardfromthe instrumentitself However arcingin faultyinsulation sparkingcausedwhen ma...

Page 5: ...or test leads Preparations for testing of power system grounding or close to it can leave personnel vulnerable to exposure caused by faults at or fed from the system under test transferred potentials...

Page 6: ...hey were new Always disconnect the test leads when changing the batteries by removing the cover which give access to the batteries Always double check the lead connections before making any measuremen...

Page 7: ...warning features should your Variable High Voltage Digital Insulation Meter be connected to a live system 1 3 Never open your Variable High Voltage Digital Insulation Meter except for battery replacem...

Page 8: ...gaOhmios 6213 IN SEW manual ingles www viaindustrial com 1 7 Your Variable High Voltage Digital Insulation Meter has a live circuit warning beeper If It is connected to a live circuit a rapid pulsatin...

Page 9: ...his bar graph is showing voltage output during the first 30 seconds of the test or during automatic discharge of circuits During the automatic discharge of the circuit tested the bar graph displays th...

Page 10: ...6 5KV 7KV 7 5KV 8KV 8 5KV 9KV 9 5KV 10KV Calculate Dielectric Absorption Ratio DAR Automatically Calculate Polarization Index PI Automatically Insulation resistance Auto Ranging on all ranges TM Bar g...

Page 11: ...Ohmios 6213 IN SEW manual ingles www viaindustrial com Medidores de aislamiento Megohmetros Digitales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com 4 CONNECTIONS INSULATOR HV 10kV VAR...

Page 12: ...5KV 5KV 10KV Measuring Range 800K 500G AUTO RANGING Accuracy 5 2 digits Power 8 x 1 5V Alkaline batteries Output Power Limit 1W Voltage Regulation Selected Voltage 20 5 of nominal value unless curren...

Page 13: ...test voltage press 10KV button 2 6 3 Insulation Resistance Measurement 5KVdc To Select 5KVdc test voltage press 5KV button 4 6 4 Insulation Resistance Measurement 2 5KVdc To Select 2 5KVdc test volta...

Page 14: ...certain time or to make comparison See Special Features for more Timer Functions 6 11 STOP test To stop the test in progress press the TEST button 3 The test will immediately stop discharge and the i...

Page 15: ...ed by a one second long beep accompanied by the HOLD message on the display DO NOT REMOVE LEADS UNTIL THE HOLD MESSAGE APPEARS ON THE DISPLAY 6 15 Replace Battery Warning Indicator If the battery ener...

Page 16: ...Polarization Index The Polarization Index or PI is the ratio of the Insulation Resistance measured at 10 Minutes divided per the Insulation Resistance measured at 1 Minute 10 Minutes after starting a...

Page 17: ...t any time before during and after the test It s your responsibility to ensure proper contact of the leads at all times Once a test is finished the testers will automatically discharge capacitive or i...

Page 18: ...6213 IN SEW manual ingles www viaindustrial com 8 PREPARATION FOR MEASUREMENT 8 1 Before testing always check the following At Power ON read the display to make sure the Replace Battery message is no...

Page 19: ...ng care to observe correct polarity Replace battery cover 9 2 Cleaning Storage Periodically wipe the case with a damp cloth and detergent Do not use abrasives or solvents If the meter is not to be use...

Page 20: ...are not live before commencing testing Secure both test leads properly to the insulation to test and use guard lead to collect surface leakage Good contacts are necessary to avoid flashing at high vol...

Page 21: ...surface of the insulator is too high and therefore the insulator may require cleaning 4 Should your insulator require cleaning follow the procedures recommended by it s manufacturer 5 For Final Test a...

Page 22: ...r characteristics may deteriorate due to many factors Their material properties may deteriorate with time and frequency use as well as stress put on to them One of the factor we will be testing is the...

Page 23: ...ormers are painted or dipped with insulating varnish large power transformers are painted with High Voltage insulating paint of very high specifications Many Applications uses insulating material to p...

Page 24: ...arranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way so as in our sole judgement to injure their stability or reliability or which have...

Reviews: