LIMITED  WARRANTY

 

We

 

warrant

 

the

 

product

 

manufactured

 

by

 

us

 

to

 

be

 

free

 

from

 

defective

 

material

 

or

 

factory

 

workmanship

 

and

 

agree

 

to

 

repair

 

or

 

replace

 

this

 

product

 

which,

 

under

 

normal

 

use

 

and

 

service,

 

disclose

 

the

 

defect

 

to

 

be

 

the

 

fault

 

of

 

our

 

manufacturing,

 

with

 

no

 

charge

 

for

 

parts

 

and

 

service.

 

If

 

we

 

are

 

unable

 

to

 

repair

 

or

 

replace

 

this

 

product,

 

we

 

will

 

make

 

a

 

full

 

refund

 

of

 

the

 

purchase

 

price.

 

Consult

 

the

 

user's

 

manual

 

for

 

proper

 

instruction

 

regarding

 

use

 

of

 

this

 

instrument.

 

Our

 

obligation

 

under

 

this

 

warranty

 

is

 

limited

 

to

 

repairing,

 

replacing

 

or

 

making

 

refund

 

of

 

this

 

test

 

equipment

 

which

 

proves

 

to

 

be

 

defective

 

within

 

twelve

 

months

 

from

 

the

 

date

 

of

 

original

 

purchase.

 

 

This

 

warranty

 

does

 

not

 

apply

 

to

 

any

 

of

 

our

 

products

 

which

 

have

 

been

 

repaired

 

or

 

altered

 

by

 

unauthorized

 

persons

 

in

 

any

 

way

 

so

 

as,

 

in

 

our

 

sole

 

judgement,

 

to

 

injure

 

their

 

stability

 

or

 

reliability,

 

or

 

which

 

have

 

been

 

subject

 

to

 

misuse,

 

abuse,

 

misapplication,

 

negligence

 

or

 

accident

 

or

 

which

 

have

 

had

 

the

 

serial

 

numbers

 

altered,

 

defaced

 

or

 

removed.

 

 

Accessories,

 

not

 

of

 

our

 

manufacture

 

used

 

with

 

this

 

product,

 

are

 

not

 

covered

 

by

 

this

 

warranty.

 

 

All

 

warranties

 

implied

 

by

 

law

 

are

 

hereby

 

limited

 

to

 

a

 

period

 

of

 

twenty

 

four

 

months,

 

and

 

the

 

provisions

 

of

 

the

 

warranty

 

are

 

expressly

 

in

 

lieu

 

of

 

any

 

other

 

warranties

 

expressed

 

or

 

implied.

 

 

The

 

purchaser

 

agrees

 

to

 

assume

 

all

 

liability

 

for

 

any

 

damages

 

or

 

bodily

 

injury

 

which

 

may

 

result

 

from

 

the

 

use

 

or

 

misuse

 

of

 

the

 

product

 

by

 

the

 

purchaser,

 

or

 

its

 

user,

 

his

 

employees,

 

or

 

others,

 

and

 

the

 

remedies

 

provided

 

for

 

in

 

this

 

warranty

 

are

 

expressly

 

in

 

lieu

 

of

 

any

 

other

 

liability

 

we

 

may

 

have

 

including

 

incidental

 

or

 

consequential

 

damages.

 

 

We

 

reserve

 

the

 

right

 

to

 

discontinue

 

models

 

at

 

any

 

time,

 

or

 

change

 

specification,

 

price

 

or

 

design,

 

without

 

notice

 

and

 

without

 

incurring

 

any

 

obligation.

 

 
 
 
 

-24-

 

Summary of Contents for 6213A-IN

Page 1: ...itales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com Medidores de aislamiento Megohmetros Digitales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com 6213A IN DIGITAL VAR...

Page 2: ...ingles www viaindustrial com TABLE OF CONTENTS Index 2 Front Panel Layout 3 Inside Lid Instructions 4 Safety precautions 5 8 Overview 9 Features 10 Connections 11 Specifications 12 Functions 13 15 Sp...

Page 3: ...AYSREADUSER SMANUALBEFOREOPERATINGTHISINSTRUMENT Useonlyonde energisedandisolated disconnectedsystem DONOTPROCEEDIFVOLTAGEPRESENT Checktestleadsfordefects Ifanycracksordamages replacewithnewtest leads...

Page 4: ...AR WARNING Thisinstrumentshould notbeusedinexplosive orinflammable environments although thereisunlikelytobea firehazardfromthe instrumentitself However arcingin faultyinsulation sparkingcausedwhen ma...

Page 5: ...or test leads Preparations for testing of power system grounding or close to it can leave personnel vulnerable to exposure caused by faults at or fed from the system under test transferred potentials...

Page 6: ...hey were new Always disconnect the test leads when changing the batteries by removing the cover which give access to the batteries Always double check the lead connections before making any measuremen...

Page 7: ...warning features should your Variable High Voltage Digital Insulation Meter be connected to a live system 1 3 Never open your Variable High Voltage Digital Insulation Meter except for battery replacem...

Page 8: ...gaOhmios 6213 IN SEW manual ingles www viaindustrial com 1 7 Your Variable High Voltage Digital Insulation Meter has a live circuit warning beeper If It is connected to a live circuit a rapid pulsatin...

Page 9: ...his bar graph is showing voltage output during the first 30 seconds of the test or during automatic discharge of circuits During the automatic discharge of the circuit tested the bar graph displays th...

Page 10: ...6 5KV 7KV 7 5KV 8KV 8 5KV 9KV 9 5KV 10KV Calculate Dielectric Absorption Ratio DAR Automatically Calculate Polarization Index PI Automatically Insulation resistance Auto Ranging on all ranges TM Bar g...

Page 11: ...Ohmios 6213 IN SEW manual ingles www viaindustrial com Medidores de aislamiento Megohmetros Digitales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com 4 CONNECTIONS INSULATOR HV 10kV VAR...

Page 12: ...5KV 5KV 10KV Measuring Range 800K 500G AUTO RANGING Accuracy 5 2 digits Power 8 x 1 5V Alkaline batteries Output Power Limit 1W Voltage Regulation Selected Voltage 20 5 of nominal value unless curren...

Page 13: ...test voltage press 10KV button 2 6 3 Insulation Resistance Measurement 5KVdc To Select 5KVdc test voltage press 5KV button 4 6 4 Insulation Resistance Measurement 2 5KVdc To Select 2 5KVdc test volta...

Page 14: ...certain time or to make comparison See Special Features for more Timer Functions 6 11 STOP test To stop the test in progress press the TEST button 3 The test will immediately stop discharge and the i...

Page 15: ...ed by a one second long beep accompanied by the HOLD message on the display DO NOT REMOVE LEADS UNTIL THE HOLD MESSAGE APPEARS ON THE DISPLAY 6 15 Replace Battery Warning Indicator If the battery ener...

Page 16: ...Polarization Index The Polarization Index or PI is the ratio of the Insulation Resistance measured at 10 Minutes divided per the Insulation Resistance measured at 1 Minute 10 Minutes after starting a...

Page 17: ...t any time before during and after the test It s your responsibility to ensure proper contact of the leads at all times Once a test is finished the testers will automatically discharge capacitive or i...

Page 18: ...6213 IN SEW manual ingles www viaindustrial com 8 PREPARATION FOR MEASUREMENT 8 1 Before testing always check the following At Power ON read the display to make sure the Replace Battery message is no...

Page 19: ...ng care to observe correct polarity Replace battery cover 9 2 Cleaning Storage Periodically wipe the case with a damp cloth and detergent Do not use abrasives or solvents If the meter is not to be use...

Page 20: ...are not live before commencing testing Secure both test leads properly to the insulation to test and use guard lead to collect surface leakage Good contacts are necessary to avoid flashing at high vol...

Page 21: ...surface of the insulator is too high and therefore the insulator may require cleaning 4 Should your insulator require cleaning follow the procedures recommended by it s manufacturer 5 For Final Test a...

Page 22: ...r characteristics may deteriorate due to many factors Their material properties may deteriorate with time and frequency use as well as stress put on to them One of the factor we will be testing is the...

Page 23: ...ormers are painted or dipped with insulating varnish large power transformers are painted with High Voltage insulating paint of very high specifications Many Applications uses insulating material to p...

Page 24: ...arranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way so as in our sole judgement to injure their stability or reliability or which have...