background image

10

Technical data and dimension sheets

Dimension drawings

Operating Instructions – OPT11D-150-0

46

10.3.2

Dimension drawing of cut-out for installation

389

250

33883737355

All dimensions are specified in mm.

Width

Height

Installation

depth

Thickness of mounting

plate

389 mm

250 mm

Approx. 70 mm

3 – 7 mm

26867257/EN – 02/2021

Summary of Contents for OPT11D-150-0

Page 1: ...26867257_0221 Drive Technology Drive Automation System Integration Services Operating Instructions Monitor OPT11D 150 0 Edition 02 2021 26867257 EN...

Page 2: ...SEW EURODRIVE Driving the world...

Page 3: ...ety technology 9 2 6 Transportation storage 10 2 7 Setup installation 10 2 8 Electrical connection 10 2 8 1 ESD protection measures 11 2 8 2 Electromagnetic compatibility EMC 11 2 9 Startup and operat...

Page 4: ...2 5 Main menu Screen settings 34 7 2 6 Main menu System settings 37 7 2 7 Main menu Info 38 8 Service 39 8 1 Waste disposal 39 9 Maintenance 40 9 1 Cleaning the screen 40 10 Technical data and dimensi...

Page 5: ...ou are unclear about any of the information in this documentation or if you require further information contact SEW EURODRIVE 1 2 Other applicable documentation Observe the corresponding documentation...

Page 6: ...mbedded safety notes Embedded safety notes are directly integrated into the instructions just before the de scription of the dangerous action This is the formal structure of an embedded safety note SI...

Page 7: ...Instructions OPT11D 150 0 7 1 7 Copyright notice 2021 SEW EURODRIVE All rights reserved Unauthorized reproduction modifica tion distribution or any other use of the whole or any part of this document...

Page 8: ...sure that all of the work listed in the following may be carried out only by qualified specialists Setup and installation Installation and connection Startup Maintenance and repairs Shutdown Disassemb...

Page 9: ...es systems and circuits in accordance with the standards of safety technology Instructed persons All work in the areas of transportation storage operation and waste disposal must be carried out by per...

Page 10: ...impact and it protects the product sufficiently During packing or unpacking products always take the impact and ESD protection into ac count and use a work envelope that is EOS ESD protected 2 7 Setu...

Page 11: ...s purpose Printed circuit boards may only be dispatched in ESD pack aging material 2 8 2 Electromagnetic compatibility EMC The product meets the requirements stipulated in the EMC Directive 2014 30 EU...

Page 12: ...cture 3 1 Basic device The following figure shows the front and rear of the device 3 4 1 2 7 6 5 A B 33877992587 A Front B Rear 1 Screen 2 Glass front 3 Retaining clamp with screw 4 Gasket 5 Connectio...

Page 13: ...tached to the rear of the device 33869298315 3 2 2 Sample type designation OPT11D 150 0 Type OPT Operator Panel Touch Built in variant 11 Control cabinet Generation D Size 150 TFT LCD display with 15...

Page 14: ...crews M4 TX20 24 V supply connector 3 4 Accessories INFORMATION The delivery does not include accessories such as 24 V voltage supply and connec tion cables If you are not sure which accessories you n...

Page 15: ...and damage to property Adhere to the notes about installation and disassembly Do not install the device alone at least 2 persons Make sure that the thickness of the mounting plate is 3 7 mm NOTICE Ri...

Page 16: ...system are subject to investigation by the local authority having jurisdiction at the time of installation All devices have to be supplied by a Class 2 power supply Expansion units Only UL and cUL ap...

Page 17: ...ns below Terminal Block Con nector Wire Size AWG Torque Lb ln X1 X100 Phoenix connect ors AWG 30 12 5 7 X1 X100 Anytek connect ors AWG 24 12 3 5 X1 X100 DECA connectors AWG 24 12 7 Usage These devices...

Page 18: ...corresponds to the line voltage The device is undamaged no damage caused by transport or storage The ambient temperature corresponds to the specification in the operating instruc tions and the namepl...

Page 19: ...kaging while it is not being used for operational purposes unless it is otherwise protected Unpack or pack the device only at safe EOS ESD workplaces If a safe workplace cannot be guaranteed it is imp...

Page 20: ...d in the delivery are ready for use 1 Make sure that the seal of the operator panel is seated evenly and without deform ation 2 Insert the screws into the mounting elements 33882793995 3 Place the mon...

Page 21: ...s OPT11D 150 0 21 5 Tighten the screw clockwise with a tightening torque of 0 8 Nm 0 2 Nm until the mounting element is pressed against the housing wall 33869333387 6 Repeat the procedure for the rema...

Page 22: ...d in the delivery for a connection to the in put current connection of the device Check the electrical specification on the nameplate of the device NOTICE Risk of damage when disconnecting or connecti...

Page 23: ...e anti static mats heel straps or air ionizers for more protection Always touch components that can be damaged by electrostatic energy at the edge or the housing Avoid contact with pins cables or circ...

Page 24: ...llows The monitor is mounted 1 Connect the DVI cable to the DVI interface of the monitor and to the DVI output of the Windows part of the MOVI C CONTROLLER of performance class power UHX85A or to anot...

Page 25: ...rence potential 2 SHIELD Shield 3 DC 24 V DC 24 V voltage supply 5 5 1 Using the 24 V supply connector with AC DC power supply unit Do the following The monitor is connected 1 Connect the grounding ca...

Page 26: ...monitor is connected The voltage supply is connected 1 Switch on MOVI C CONTROLLERs of performance class progressive UHX65A or power UHX85A 2 If the monitor does not turn on automatically press the P...

Page 27: ...Device structure 2 12 The following figure shows the control panel of the monitor 1 5 6 2 3 4 33735762443 Item Button LED Description 1 To open the menu press the Menu button 2 To select a tab use th...

Page 28: ...und 7 2 Configuration menu The settings of the main menu during configuration appear on the left side of the screen When you select a main menu item the associated sub menu items appear in the center...

Page 29: ...figuration menu Operating Instructions OPT11D 150 0 29 Select input Scan inputs 33885320459 7 2 2 Main menu Image settings Image adjustments 33885400843 Image adjustments Backlighting 34216305803 2686...

Page 30: ...ration Configuration menu Operating Instructions OPT11D 150 0 30 Image adjustments Brightness 34216309387 Image adjustments Contrast 34216312971 Image adjustments Sharpness 33885404427 26867257 EN 02...

Page 31: ...n Configuration menu Operating Instructions OPT11D 150 0 31 Image adjustments Gamma 34217968139 7 2 3 Main menu Color setting Color adjustment 33885408011 Color adjustment Theme 33885440651 26867257 E...

Page 32: ...User 34217972875 If the sub menu item Color adjustment Color temp User is selected the other sub menu items Red green blue are active Color adjustment Color temp 4200K to 9500K 34217976459 If the sub...

Page 33: ...ctions OPT11D 150 0 33 Color adjustment Red 34218069643 Color adjustment Green 34218073611 Color adjustment Blue 34218077195 Color adjustment Saturation The sub menu is inactive Color adjustments Colo...

Page 34: ...50 0 34 7 2 4 Main menu VGA settings VGA settings INFORMATION The following settings are available only if the VGA signal is present 34218080779 7 2 5 Main menu Screen settings Screen settings 3388544...

Page 35: ...n Configuration menu Operating Instructions OPT11D 150 0 35 Screen settings Screen timeout 33885448587 Screen settings Orientation 33885477259 Screen settings Horizontal position 33885465355 26867257...

Page 36: ...7 Operation Configuration menu Operating Instructions OPT11D 150 0 36 Screen settings Vertical position 33885469323 Screen settings Transparency 33885473291 26867257 EN 02 2021...

Page 37: ...T11D 150 0 37 7 2 6 Main menu System settings System settings 33885486731 System settings Restore factory settings 33885515403 System settings Restore user settings The sub menu is inactive System set...

Page 38: ...7 Operation Configuration menu Operating Instructions OPT11D 150 0 38 7 2 7 Main menu Info Info 33885503499 Info Info 33885519755 Info Mode info 33885507467 26867257 EN 02 2021...

Page 39: ...hazardous to health and the environment These materials must be collected and disposed of separately Oil and grease Collect used oil and grease separately according to type Ensure that the used oil i...

Page 40: ...nance 9 1 Cleaning the screen NOTICE Dirt particles can scratch the surface of the screen Do not apply pressure when cleaning the screen To remove dust and dirt particles clean the surface of the scre...

Page 41: ...ion W H D 399 260 74 mm Cut out dimension W H 389 250 mm Installation depth Installation depth including clearance 70 mm 170 mm Weight Approx 6 5 kg Cooling Fan free passive cooling Protection materia...

Page 42: ...3 F 10 1 6 Ambient conditions Ambient conditions Operating temperature 0 C to 50 C Storage temperature 10 C to 60 C Max operating height Up to h 3000 m Max storage height Up to h 5000 m Humidity 10 9...

Page 43: ...DC 24 V voltage supply Terminal socket 3 pin No Signal 2 1 3 1 GND 2 SHIELD 3 24 V DC 10 2 2 DisplayPort interface DisplayPort interface No Signal No Signal 19 1 2 20 1 TX0 11 GND 2 GND 12 TX3 3 TX0...

Page 44: ...al 1 C1 C2 C5 C5 24 C3 C4 17 33883932171 1 13 NC 2 Rx2 14 5V 3 GND 15 GND 4 NC 16 HP 5 NC 17 6 SCL 18 Rx0 7 SDA 19 GND 8 NC 20 NC 9 21 NC 10 Rx1 22 GND 11 GND 23 RxC 12 NC 24 RxC C1 RED C4 HSYNC C2 GR...

Page 45: ...rating Instructions OPT11D 150 0 45 10 3 Dimension drawings 10 3 1 Dimension drawing of device 399 411 387 399 65 29 5 105 65 29 5 105 28 67 134 63 67 63 67 85 69 1 260 13 7 6 6 6 272 198 50 6 6 33883...

Page 46: ...perating Instructions OPT11D 150 0 46 10 3 2 Dimension drawing of cut out for installation 389 250 33883737355 All dimensions are specified in mm Width Height Installation depth Thickness of mounting...

Page 47: ...tibility 11 Embedded safety notes 6 EMC Directive 42 ESD protection measures 11 F Functional safety technology Safety note 9 G Grounding 23 H Hazard symbols Meaning 6 Humidity 42 I Installation 20 Dim...

Page 48: ...symbols 6 Operation 11 Preliminary information 8 Service maintenance 11 Startup 11 Structure of embedded 6 Structure of section related 6 Scope of delivery 14 Screen Cleaning 40 Section related safety...

Page 49: ......

Page 50: ......

Page 51: ......

Page 52: ...SEW EURODRIVE Driving the world SEW EURODRIVE GmbH Co KG Ernst Blickle Str 42 76646 BRUCHSAL GERMANY Tel 49 7251 75 0 Fax 49 7251 75 1970 sew sew eurodrive com www sew eurodrive com...

Reviews: