Operating Instructions – MOVITRANS® THM20C / THM20E Pick-Ups
35
6
Technical data of THM20E
Technical Data
Peak power P
1
as
function of the con-
tinuous power P
2
The following characteristic curves show the peak power P
1
of the pick-up as a function
of the continuous power P
2
against the following variables:
• Line cable current I
L
[A]
• Line cable distance x [mm]
I
L
= 60 A,
ϑ
= 45 °C, E
1
The following figure shows the peak power P
1
as a function of the continuous power P
2
with the following values:
• Line cable current I
L
= 60 A
• Ambient temperature
ϑ
= 45 °C
• Installation condition = E
1
The continuous power of the pick-up is calculated using the following formula:
2712942475
P
1
= Peak power of the pick-up
P
2
= Continuous power of the pick-up
P
3
= Minimal power of the pick-up
t
1
=
Time (here: t1 < 400 s) during which the peak power is present at the pick-up
T =
Cycle duration
P
P t
P T t
T
with t
s
2
1
1
3
1
1
400
=
× +
−
(
)
<
2713083147
[1]