![SEW-Eurodrive MOVIGEAR B Manual Download Page 38](http://html1.mh-extra.com/html/sew-eurodrive/movigear-b/movigear-b_manual_1250164038.webp)
5
Appendix
Connection of an external safety controller for STO
Manual – MOVIGEAR
®
B
38
5.4.4
Connection via M12 plug connectors – group disconnection
The following figure shows a connection example for disconnection of group drives
with a safety controller:
X5502
STO
X5503
STO
2
4
4
2
[3]
[4]
X5502
STO
X5503
STO
[3]
[4]
4
2
2
4
[2]
[1]
DOn_P
DOn_M
9007202062818699
[1] Installation space
[3] MOVIGEAR
®
B
[2] Safety controller
[4] Plug connector for STO
INFORMATION
When wiring the STO signals, possible faults in plug connectors and cables/lines
have to be considered (see EN ISO 13849-2) and the installation has to be designed
according to the required safety class. MOVIGEAR
®
does not detect short circuits in
the supply line. SEW‑EURODRIVE therefore recommends to connect only STO sig-
nals to the STO input using a two-core cable, as shown in the figure.