Description of functions
Project Planning
3.5
Description of functions
3.5.1
Possible MOVIGEAR
®
functions
The MOVIGEAR
®
functions are used to control a drive individually. The different
functions is assigned a specific number of process data words. This means the
individual drives share the 64 available process data (PD).
•
1 PD drive function
The 1 PD drive function allows for controlling a MOVIGEAR
®
with fixed speeds by
means of a process data word. You can configure 4 ramp sets and 6 fixed speeds by
clicking the [Ramps] and [Fixed speeds] buttons.
•
2 PD drive function
The 2 PD drive function allows for controlling a MOVIGEAR
®
with a user-specific
speed by means of two process data words. You can configure 4 ramp sets by
clicking the [Ramps] button.
•
3 PD drive function
The 3 PD drive function allows for controlling a MOVIGEAR
®
with a user-specific
speed by means of three process data words. The third process data word can be
used for controlling the local inputs/outputs or for displaying the actual current. You
can configure 4 ramp sets by clicking the [Ramps] button.
•
1(2) PD axis function
The 1(2) PD axis function allows for controlling the positioning functions integrated
in MOVIGEAR
®
. This is achieved either by means of fixed speeds or by a user-
defined speed. You can configure 4 ramp sets by clicking the [Ramps] button. The
relevant positioning function is configured in the MOVIVISION
®
software (see
MOVIGEAR
®
SNI system manual, chapter 11).
12134AEN
12135AEN
12136AEN
12137AEN