22
Operating Instructions – 10 kW Supply Module with Integrated Braking Resistor
5
Settings for EtherCAT-based system bus
Startup
5.3
Settings for EtherCAT-based system bus
Please note the following when using an EtherCAT-based system bus:
• Set the 4 DIP switches on the supply module to position "E".
• In this variant, switches S1, S2, S3 and S4 on the supply module do not have any
function.
• Set the DIP switch LAM to
setting "1"
at the
last
axis module in the system. In all
other axis modules, the LAM DIP switch is set to "0" position, see "MOVIAXIS
®
Multi-
Axis Servo Inverter" operating instructions in chapter "Settings with EtherCAT-based
system bus".
62503axx
Figure 7: DIP switch settings on the supply module
[1]
Settings for EtherCAT operation: All 4 switches set to "E"
[2]
DIP switches S1, S2, S3 and S4 and X12 have no functions
[2]
[1]