8
Service
Device replacement in MOVISUITE®
Operating Instructions – MOVI-C
®
FIELD CONTROLLER standard/advanced
121
8.5.4
Device replacement
1. Observe the safety notes.
2. When you replace the device including the electronics cover, you also have to
carry out the steps described in chapter "Replacing the electronics cover".
3. Remove the defective device. Observe the notes in chapter "Mechanical Installa-
tion".
4. Compare the data on the nameplate of the old device with the nameplate data of
the new device.
INFORMATION
Always replace the decentralized controller with a decentralized controller that has
the same properties.
5. Install the device. Observe chapter "Mechanical installation".
6. Perform the installation according to the "Electrical installation" chapter.
7. Remove the SD memory card from the previous electronics cover. Insert this SD
memory card in the new electronics cover.
8. Place the electronics cover onto the connection box and screw it on.
9. Supply the device with voltage.
10. Check the new device for proper functioning.
8.6
Device replacement in MOVISUITE®
8.6.1
Configuration data update
INFORMATION
When replacing a
MOVI‑C
®
FIELD CONTROLLER, observe the information in
chapter Installation and in the "
INFORMATION
For information on replacing the drives, refer to the manual of the corresponding ap-
plication inverter.
INFORMATION
The variable values permanently stored on the
MOVI‑C
®
FIELD CONTROLLER are
not stored on the OMH memory card by default. To store the variable values on the
OMH memory card, program a corresponding IEC program.
Do the following when replacing a
MOVI‑C
®
FIELD CONTROLLER
:
1. In MOVISUITE
®
, open the configuration of the
MOVI‑C
®
FIELD CONTROLLER
.
2. Open the "Data management" submenu.
26872137/EN – 12/2021