Operating instructions – BMG..T Double Disc Brakes for Stage Applications 

5

2

Safety and warning instructions

Safety Notes

2

Safety Notes

The requirements for the emergency stop relay and the permitted circuit variants are
specified in detail in the following sections and must be strictly observed.

The system/machine manufacturer must perform a system/machine-specific
risk analysis.
  The use of BMG..T double disc brakes for stage applications
must be taken into account in this analysis.
 

The switching equipment of the external voltage supply for the brakes must at
least comply with category 3 to EN 954-1 or with a comparable national stan-
dard.  

In normal operation, the manual release lever for the brake must not be
attached. This prevents the brake from being released unintentionally. The
brake must not be converted to enable lockable manual release.

General 
information

Please also consider the supplementary safety notes in the individual sections
of these operating instructions.

During and after operation, the brakes may have live and moving parts and their
surfaces may be hot.

All work related to transport, putting into storage, setting up/mounting,
connection, startup, maintenance and repair may only be performed by trained
personnel observing

– The corresponding detailed operating instruction(s) and wiring diagrams
– The specific regulations and requirements for the system
– National/regional regulations governing safety and the prevention of accidents

Severe injuries and damage to property may result from

– Incorrect use
– Incorrect installation or operation
– Removal of required protective covers or the housing when this is not permitted

If work is carried out on the electrical section of the system, the supply voltage
must be disconnected.

Designated use

The BMG..T double disc brakes are certified as safe components of mobile flying
equipment or rigging systems for stage applications to DIN 56925, DIN 56921-11 and
DIN 56950. Drives fitted with BMG..T brakes must fulfill the requirements in the
above standards. The "Driving mechanisms" section in particular must be observed.

Technical data and information about the permitted conditions can be found on the
nameplate and in the documentation.

BMG..T double disc brakes cannot be retrofitted.

It is essential to observe all the specified information!

Transportation 

Inspect the shipment for any damage that may have occurred in transit as soon as
you receive the delivery. Inform the shipping company immediately. It may be
necessary to preclude startup.

 

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Summary of Contents for BMG T Series

Page 1: ...its Drive Electronics Drive Automation Services BMG T Double Disc Brakes for Stage Applications Operating Instructions A6 C86 Edition 06 2004 11295228 EN Buy www ValinOnline com Phone 844 385 3099 Ema...

Page 2: ...SEW EURODRIVE Driving the world Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Page 3: ...c structure 7 4 2 Unit designation 7 5 Installation Startup 8 5 1 Mechanical installation 8 5 2 Electrical installation 8 5 3 Startup 8 6 Inspection Maintenance 9 6 1 Inspection and maintenance period...

Page 4: ...ut servicing and should be kept close to the unit This document supplements the AC Motors Asynchronous Servomotors operating instructions and limits the application notes according to the following in...

Page 5: ...repair may only be performed by trained personnel observing The corresponding detailed operating instruction s and wiring diagrams The specific regulations and requirements for the system National reg...

Page 6: ...ions Product certificate of the Rheinisch Westf lischer Technischer berwachungs Vere in e V RW T V The certification reports accompanying the respective certificates must be observed The conditions ar...

Page 7: ...Basic structure of the BMG T brake 42 Brake end shield 49 Pressure plate 50 Brake spring 52 Brake stationary disc 53 Manual release 54 Complete brake coil body 56 Stud 57 Conical coil spring 58 Hex n...

Page 8: ...the voltage is switched off Connect the brake according to the wiring diagram supplied with the brake The supply voltage must lie within the rated voltage range of the brake coil see Sec Technical Dat...

Page 9: ...he employer s liability insurance association brakes for stage applications must be checked once a year The BMG T brakes can only be disassembled by trained personnel 6 2 Checking the dual circuit bra...

Page 10: ...f the distance blocks until the air gap is applied completely at the bridged brake disc 6 Set the working air gap for the brake disc in the power flow to 0 25 mm At this point the brake motor is free...

Page 11: ...function Inspection Maintenance 54248AXX Figure 3 Checking the dual circuit brake function with distance blocks 1 Distance block 3x 2 Air gap 3 Adjusting screw 4 Brake disc not in the power flow 5 Bra...

Page 12: ...ent and rigging system To check the backup and safety factors in a single test 250 of the permitted load torque is applied as a static reference torque 6 3 Customer service Please have the following i...

Page 13: ...lowing brake control systems in combination with brakes in the BMG T series If you want to install a different brake control system please contact SEW EURODRIVE to discuss the possibilities Brake type...

Page 14: ...supply 2 772 2 Direct current in BSG operation 4 152 230 AC 208 233 0 36 0 46 0 66 240 AC 234 261 0 32 0 41 0 59 290 AC 262 293 0 29 0 36 0 53 400 AC 370 414 0 20 0 26 0 37 440 AC 415 464 0 18 0 24 0...