6. Fault finding and troubleshooting
The table provided below will help you to solve potential problems
occurring during operation. In the event that you cannot find a suitable
solution for a problem, please contact our customer service department, see
section "Customer service" on the last pages of this instructions document.
Fault
Cause
Remedy
The appliance does not
operate after pressing the
Start/Stop button
.
Maybe the appliance is not connected to
a power supply.
Please check the connection line with
mains plug (K) for correct connection to
the mains supply.
The display element Error
is flashing.
No strainer support inserted.
Insert the required strainer support (C
or D). Then, press the Start/Stop button
.
Bracket closure is open.
Close the bracket closure (B). Press the
Start/Stop button
.
The water reservoir is empty or not
assembled or the water fill level is below
the mark MIN.
Please fill the water reservoir (L)
appropriately and assemble. Press the
Start/Stop button
.
The valve at the bottom of the water
reservoir is clogged.
Clean the water reservoir, see section
"5. Cleaning, care and maintenance".
Unblock the valve by slightly pressing
against it from underneath.
Press the Start/Stop button
.
The float used for fill level measurement
in the water reservoir is blocked.
Clean water reservoir, see section
"5. Cleaning, care and maintenance".
Unblock the float by lightly shaking the
water reservoir.
Press the Start/Stop button
.
Water is dripping from the
brewing unit.
The bracket closure was not closed
properly.
Danger of scalding!
Immediately cancel the brewing process
by pressing the Start/Stop button
and wait until the display element
extinguishes. Carefully fold the bracket
closure (B) upwards, remove the relevant
strainer support (C or D), check for faults/
irregularities and reassemble. Close the
brewing unit (A) by firmly pressing the
bracket closure (B) downwards.
The appliance performs
the brewing phase, but no
beverage is poured.
The strainer support is clogged.
Clean the strainer support, see section
"5. Cleaning, care and maintenance".
The water reservoir was not assembled
properly.
Please check if the water reservoir (L) is
assembled properly.
The water reservoir was removed during
the brewing process.
Reassemble the water reservoir (L) and
continue or repeat brewing process.