2.4.1 Cable Termination and Hirschmann Models

All 206 models with a cable termination or Hirschmann connector vent through the cable to 
maintain proper accuracy. Connection to the unit should be made in a junction box that is vented 
to atmosphere, with care taken to ensure that the end of the cable is not blocked or sealed. 

The following junction box configuration is a recommended method for connecting to 206 units 
in order to achieve a moisture resistant and vented connection. 

Termination

Junction Box

Strain Relief

Part Number:

Q1388PCE

3237 Heyco Flex fitting

Dimensions:

4.92” x 2.95” x2.95”

2.50” Long

Manufacturer:

Hoffman Engineering Co.

900 Ehlen Drive

Anoka, MN 55303

(612) 421-2240

Heyco

Kenilworth, NJ 07033

(201) 245-0033

(800) 526-4182

•  Drill one ½” dia. Hole at each of the junction box for cable strain reliefs.
•  Drill and tap one ½” – 13 NC hole in bottom of junction box and install loosely one ½” – 13 

NC plastic or stainless steel screw. The clearance between threads serves as ventilation. 

•  Install cable strain reliefs in ½” holes. 
•  Mount junction box and install cables.
•  A desiccant pack can be placed in the junction box for additional humidity protection.

NOTES:

 

The above directions are for cable termination models. Hirschmann and 
conduit connections require slight modifications at the discretion of the installer.

Terminal Block Connections

All 206 models with terminal block connections are vented through a porous plug on the 
connected; no additional venting is required during installation.

Summary of Contents for 206

Page 1: ...Model 206 Operating Instructions Setra Systems Inc 159 Swanson Road Boxborough MA 01719 800 257 3872 www setra com ...

Page 2: ...mperature limits of the 206 are 40 to 185 F 40 to 85 C The compensated temperature range is 4 to 176 F 20 to 80 C 2 3 Pressure Fittings Typically standard pipe fittings and procedures should be used However for pressure ranges in excess of 500 PSIG 35 Bar we suggest the use of a sealant such as Loctite Hydraulic Sealant Excessive torqueing of metal fittings may cause a slight zero shift The use of...

Page 3: ...o 900 Ehlen Drive Anoka MN 55303 612 421 2240 Heyco Kenilworth NJ 07033 201 245 0033 800 526 4182 Drill one dia Hole at each of the junction box for cable strain reliefs Drill and tap one 13 NC hole in bottom of junction box and install loosely one 13 NC plastic or stainless steel screw The clearance between threads serves as ventilation Install cable strain reliefs in holes Mount junction box and...

Page 4: ...onitor White 2 Output connect to controller or monitor Black 2 Excitation connect to return of 12 28 VDC power supply Shielding 4 Connect to system or earth ground NOTE 1 Model 206 can be wired as a three wire device by connecting output and excitation and shield to a common ground However accuracy will be reduced because of voltage drops in the leads NOTE 2 Mating Hirschmann connects GDM3009J Hir...

Page 5: ...to improve electrical noise rejection 4 0 Calibration Every model 206 is factory calibrated and should require no field adjustment Whenever possible any zero and or span offsets should be corrected by software adjustments in the user s control system However both zero and span adjustments are accessible by removing the pan head screws and turning the zero and span potentiometer screws inside Pan H...

Page 6: ...hipping and billing instructions Full description of the malfunctions Identify any hazardous material used with the product NOTES Please remove any pressure fittings and plumbing that you have installed and enclose any required mating electrical connectors and wiring diagrams Allow approximately 3 weeks after receipt at Setra for the repair and return of the unit Non warranty repairs will not be m...

Page 7: ...ETRA is notified in advance of and the product is returned to SETRA transportation prepaid Unless otherwise specified in a manual or warranty card or agreed to in a writing signed by a SETRA officer SETRA pressure and acceleration products shall be warranted for one year from date of sale The foregoing warranty is in lieu of all warranties express implied or statutory including but not limited to ...

Page 8: ...of Substances in Contact with the Product SECTION 4 Return Information Reason for return and symptoms of malfunction ____________________________________________ _____________________________________________________________________________________________ If you have a warranty claim Who did you buy the product from ________________________________________________________ Give the supplier s invoi...

Reviews: