13
ENGLISH
DANGER! Electrical current!
Maintenance or repair work on the luminaire may
only be carried out by qualified electricians.
Disconnect the mains plug before opening the
lamp!
The relevant safety regulations for working on
electrical systems apply.
Failure
Error
Possible
cause
Solution
Luminaire wit-
hout function
Disconnected
from supply grid
Check the connection
to the grid
Failure of only
one LED module
Defect LED
module
Repair necessary
Failure of two
LED modules
Defect power
adapter or faulty
rotary control
(only XLD-2)
Repair necessary
Luminaire cannot
be dimmed
Faulty potentio-
meter
Repair necessary
ATTENTION!
Make sure that your suspension point is desig-
ned for the weight of the luminaire.
Ring nut
Star knob
WARNING! Risk of injury!
Be sure to fix the star knob by turning it clockwise.
This way you avoid accidents and injuries.
Operation (XLD-2)
The
ALDEBARAN
®
XLD-2
light can be controlled via
the two rocker switches and the rotary control (only
with dimmable versions) on the control unit. The con-
trol unit is integrated in the supply line. Two lighting
modules are switched per toggle switch. (ON / OFF).
Turning the potentiometer clockwise increases the
illuminance, counterclockwise decreases the illumi-
nance. (Only for dimmable versions)
Potentiometer
Rocker switches
ON / OFF
Control unit