Jumpers
Jumpers
ON
OFF (Default)
J1
Power on
Power off
J2
Not used
Not used
J3
Cyclic opening
No cyclic opening
J4
Mono-stable
Bi-stable
Start up
WARNING
If no optional operation lock device is installed, make sure the KEY input is short circuited with the COM input. Otherwise
the equipment cannot be started.
If no safe close device (internal and external) is installed, make sure the SAFE CLOSE input is short circuited with the
COM input and the jumper INT/EXT (Part. C pag. 17) in EXT. Otherwise the equipment cannot be started.
WARNING
For correct automatism functions and to guarantee the optimisation of the parameters that regulate wing movement,
adjust wing weight using dip switches
S1
and
S2
as previously indicated.
Position wings ~20 cm from total closure. Turn the power switch to 1 to power the equipment.
The automatism resets limits to reduced speed first completely opening and then closing.
WARNING
If necessary, make a dynamometric control to verify any slide friction, turn off the equipment and remove the gear motor
unscrewing the specific rubber supports.
Eliminate friction causes and start the equipment again repeating the above-described movement.
Multi-logic selector not installed:
when the equipment finishes limit reset it is ready to work in 2 RADAR logic.
Multi-logic selector installed:
when the equipment finishes limit reset it is ready to work and is positioned in the
“STOP CLOSED” logic.
At the end of reset the equipment is ready for use; check correct sensor operations for opening command and safety con-
trol. Also check anti-crushing sensitivity; if the value requires increasing and decreasing, see the advanced selector manu-
al.
To test automatism operations without connections to the open command device use the START button on the unit (see
Fig. 28
)
J1
: activates motor power supply in completely closed position to generate continual
drive even in the wings stopped and closed position.
J2
: not used
J3
: cyclic opening generator to test door operations;
J4
: KEY signal operating type selection (see external peripheral connector
description): mono-stable (Activation time 500 ms) or bi-stable
Installation Instruction
21
LIGHT MILLENNIUM
Summary of Contents for LIGHT MILLENIUM